@sunzhenchuan007

Family: srf_pipe_tube_bushing
Anchor: STAUFF Catalogue 1 — STAUFF Clamps — English, version 06/2026, catalogue page 175. (official catalogue PDF)

  • Product/type: Pipe / Tube Bushing, type SRF.
  • Scope is the single split bushing used to centre a pipe/tube in a through-hole. Pipe/tube, panel/reservoir wall and mounting hardware are excluded.
  • Expected solids = 1.
  • Duplicate search was completed before cropping using “SRF”, “pipe/tube bushing”, “through-hole centring bushing”, the proposed name and similar collar/grommet/spacer-ring mechanisms across current designs/, all Issues, all PRs and the old family corpus. No equivalent was found. The current speaker-pole socket, Issue [family] duct_takeoff_starting_collar #28 duct collar and old spacer_ring are materially different interfaces and are documented in rejected-cases.md.

Claim it: self-assign, then re-verify the evidence below before coding.
Done = one scoped PR (designs/srf_pipe_tube_bushing/ only) that closes this issue.
Start here: AGENTS.md + docs/DESIGN_SPEC.md.

Reference images

待用户手动补充官方工程图和产品照片。

Dimension table

All dimensions are millimetres. Each line is one real catalogued D1 row.

D1 D2 H1 H2 Compatible wall thickness S D3 mounting bore
6 18 22 4 4…12 10
8 20 22 4 4…12 12
10 22 22 4 4…12 14
12 24 22 4 4…12 16
14 26 22 4 4…12 18
15 28 22 4 4…12 20
16 28 22 4 4…12 20
18 30 22 4 4…12 22
20 32 22 4 4…12 24
22 34 22 4 4…12 26
25 38 22 4 4…12 30
28 41 22 4 4…12 33
30 43 22 4 4…12 34
35 48 22 4 4…12 40
38 51 22 4 4…12 43
42 55 22 4 4…12 47

Standard material codes are PP (natural-colour polypropylene) and SA87 (black 87 Shore-A thermoplastic elastomer). The printed code form is SRF-[D1]-[PP|SA87]. The 4…12 mm S range describes compatible panel/reservoir wall thickness; it is not an invitation to scale unshown internal geometry.

Parameters to verify at claim

Parameter Type Allowed values / source
tube_od discrete row key, mm the 16 D1 rows above
outer_diameter derived, mm D2
height derived, mm H1
flange_height derived, mm H2
mounting_bore derived, mm D3
compatible_wall_thickness metadata range, mm 4…12
material_code discrete metadata PP, SA87

Sampling must choose a complete D1 row. Coverage should include D1 6, the 15/16 pair that shares D2/D3, a middle row and D1 42.

Engineering constraints

Entity division and engineering constraints

  1. Generate one split bushing solid with the flange/retaining profile visible in the official section and product image.
  2. D1 and D2 must be concentric; D3 is the external mounting-bore requirement and must remain coupled to the selected row.
  3. Overall axial height must match H1 and the flange feature H2.
  4. Preserve the insertion split/opening. Do not turn the part into a featureless closed spacer ring.
  5. Four benchmark views must expose the split, centre bore, flange and axial section.
  6. Validate one positive-volume solid, through bore D1, catalogued envelope and row membership.

Unmarked-dimension risk

Split width, retaining-lip depth, flange/taper profile, local radii and deformation during plug-in installation are not fully dimensioned. Use only deterministic proportion values for them. S is compatibility metadata, so do not infer a hidden wall, reservoir geometry or a continuously variable bushing body from S. Do not guess material deformation or internal reinforcement.