You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Scope is the single split bushing used to centre a pipe/tube in a through-hole. Pipe/tube, panel/reservoir wall and mounting hardware are excluded.
Expected solids = 1.
Duplicate search was completed before cropping using “SRF”, “pipe/tube bushing”, “through-hole centring bushing”, the proposed name and similar collar/grommet/spacer-ring mechanisms across current designs/, all Issues, all PRs and the old family corpus. No equivalent was found. The current speaker-pole socket, Issue [family] duct_takeoff_starting_collar #28 duct collar and old spacer_ring are materially different interfaces and are documented in rejected-cases.md.
Claim it: self-assign, then re-verify the evidence below before coding. Done = one scoped PR (designs/srf_pipe_tube_bushing/ only) that closes this issue. Start here:AGENTS.md + docs/DESIGN_SPEC.md.
Reference images
待用户手动补充官方工程图和产品照片。
Dimension table
All dimensions are millimetres. Each line is one real catalogued D1 row.
D1
D2
H1
H2
Compatible wall thickness S
D3 mounting bore
6
18
22
4
4…12
10
8
20
22
4
4…12
12
10
22
22
4
4…12
14
12
24
22
4
4…12
16
14
26
22
4
4…12
18
15
28
22
4
4…12
20
16
28
22
4
4…12
20
18
30
22
4
4…12
22
20
32
22
4
4…12
24
22
34
22
4
4…12
26
25
38
22
4
4…12
30
28
41
22
4
4…12
33
30
43
22
4
4…12
34
35
48
22
4
4…12
40
38
51
22
4
4…12
43
42
55
22
4
4…12
47
Standard material codes are PP (natural-colour polypropylene) and SA87 (black 87 Shore-A thermoplastic elastomer). The printed code form is SRF-[D1]-[PP|SA87]. The 4…12 mm S range describes compatible panel/reservoir wall thickness; it is not an invitation to scale unshown internal geometry.
Parameters to verify at claim
Parameter
Type
Allowed values / source
tube_od
discrete row key, mm
the 16 D1 rows above
outer_diameter
derived, mm
D2
height
derived, mm
H1
flange_height
derived, mm
H2
mounting_bore
derived, mm
D3
compatible_wall_thickness
metadata range, mm
4…12
material_code
discrete metadata
PP, SA87
Sampling must choose a complete D1 row. Coverage should include D1 6, the 15/16 pair that shares D2/D3, a middle row and D1 42.
Engineering constraints
Entity division and engineering constraints
Generate one split bushing solid with the flange/retaining profile visible in the official section and product image.
D1 and D2 must be concentric; D3 is the external mounting-bore requirement and must remain coupled to the selected row.
Overall axial height must match H1 and the flange feature H2.
Preserve the insertion split/opening. Do not turn the part into a featureless closed spacer ring.
Four benchmark views must expose the split, centre bore, flange and axial section.
Validate one positive-volume solid, through bore D1, catalogued envelope and row membership.
Unmarked-dimension risk
Split width, retaining-lip depth, flange/taper profile, local radii and deformation during plug-in installation are not fully dimensioned. Use only deterministic proportion values for them. S is compatibility metadata, so do not infer a hidden wall, reservoir geometry or a continuously variable bushing body from S. Do not guess material deformation or internal reinforcement.
Family:
srf_pipe_tube_bushingAnchor: STAUFF Catalogue 1 — STAUFF Clamps — English, version 06/2026, catalogue page 175. (official catalogue PDF)
solids = 1.designs/, all Issues, all PRs and the old family corpus. No equivalent was found. The current speaker-pole socket, Issue [family] duct_takeoff_starting_collar #28 duct collar and oldspacer_ringare materially different interfaces and are documented inrejected-cases.md.Claim it: self-assign, then re-verify the evidence below before coding.
Done = one scoped PR (
designs/srf_pipe_tube_bushing/only) that closes this issue.Start here:
AGENTS.md+docs/DESIGN_SPEC.md.Reference images
待用户手动补充官方工程图和产品照片。
Dimension table
All dimensions are millimetres. Each line is one real catalogued D1 row.
Standard material codes are PP (natural-colour polypropylene) and SA87 (black 87 Shore-A thermoplastic elastomer). The printed code form is
SRF-[D1]-[PP|SA87]. The 4…12 mm S range describes compatible panel/reservoir wall thickness; it is not an invitation to scale unshown internal geometry.Parameters to verify at claim
tube_odouter_diameterheightflange_heightmounting_borecompatible_wall_thicknessmaterial_codeSampling must choose a complete D1 row. Coverage should include D1 6, the 15/16 pair that shares D2/D3, a middle row and D1 42.
Engineering constraints
Entity division and engineering constraints
Unmarked-dimension risk
Split width, retaining-lip depth, flange/taper profile, local radii and deformation during plug-in installation are not fully dimensioned. Use only deterministic
proportionvalues for them. S is compatibility metadata, so do not infer a hidden wall, reservoir geometry or a continuously variable bushing body from S. Do not guess material deformation or internal reinforcement.