Conventional mean-line design modelers do not allow for effective modelling of choking effects, particularly as the flow becomes sonic at the exit of the stage.
As such, an additional feature should be added to allow for the modelling of choking effects.
Conventional mean-line design modelers do not allow for effective modelling of choking effects, particularly as the flow becomes sonic at the exit of the stage.
As such, an additional feature should be added to allow for the modelling of choking effects.