Skip to content

Complete electrical and thermal safety review #6

Description

@ReidSurmeier

The wiring packet records two 5 V supplies, protective earth distribution, relay-switched LED-panel power, an always-on controller supply, three fans, an AHT20 sensor, and six panels. Documentation is not a substitute for a qualified physical inspection.

Human safety review:

  • verify protective-earth continuity to both power supplies and exposed conductive parts
  • confirm conductor gauges, fusing, strain relief, terminal torque, polarity, clearance, and enclosure airflow
  • measure steady-state and startup current on controller and display branches
  • test relay isolation, START and STOP behavior, UPS power-loss behavior, and thermal response under representative load
  • decide whether a physical thermal cutoff is required

Acceptance criteria:

  • dated measurements and inspector identity are preserved in approved records
  • any unsafe condition blocks public operation until corrected
  • resulting wiring or threshold changes update the BoM, diagram source, generated artifacts, tests, and conservation manual.

Activity

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment