Skip to content

Question: Not able to go past Pre-Charge #363

@kushagra101010

Description

@kushagra101010

Before you post

Your Question
We are using Codico whitebeet EV board as EV simulator.
We are reaching this precharge stage and when it matches, EV simulator performs shutdown.

Below given is the UART based logs:
[ 46.276] [NOTICE] V2GAPP: Received event 'Ready for pre charging'
[ 46.276] [NOTICE] V2GAPP: stxXBAR_V2G_SendXBARStatus_EmptyMsg() - SubAdd = 0xC5
[ 46.277] [NOTICE] V2GAPP: stxXBAR_V2G_SendXBARStatus_EmptyMsg() - SubAdd = 0xC6
[ 46.425] [NOTICE] V2GAPP: Received event 'DC charge parameters changed'
[ 46.426] [NOTICE] V2GAPP: Received event 'Ready for charging'
[ 46.427] [NOTICE] V2GAPP: stxXBAR_V2G_SendXBARStatus_EmptyMsg() - SubAdd = 0xC7
[ 46.580] [NOTICE] V2GAPP: Received event 'DC charge parameters changed'
[ 46.735] [NOTICE] V2GAPP: Received event 'DC charge parameters changed'
[ 46.890] [CRIT ] V2GLIB: WRONG_SUBELEMENT_COUNT: The number of a subelement of a message that can appear several types is either too large or too small
[ 47.398] [NOTICE] V2GSVC: TCP: We were disconnected from the server
[ 47.398] [NOTICE] V2GAPP: Received event 'Session stopped'
[ 47.399] [NOTICE] V2GAPP: stxXBAR_V2G_SendXBARStatus_EmptyMsg() - SubAdd = 0xCB
[ 47.521] [NOTICE] V2GCPS: stxXBAR_V2GCPS_NotifyHandler()
[ 47.521] [NOTICE] V2GCPS: # V2GCPS_INFOTYPE_CP_DUTY_CYCLE
[ 47.522] [NOTICE] V2GCPS: Duty cycle is 57 permill
[ 48.928] [NOTICE] SLAC: stxSLAC_Stop()

Please let us know reason for the error: [ 46.890] [CRIT ] V2GLIB: WRONG_SUBELEMENT_COUNT: The number of a subelement of a message that can appear several types is either too large or too small
This will help us correcting it at our charger side.