TriageCore — Resource Estimation Methodology

Overview

TriageCore records the estimated resource consumption of every agentic coding task it orchestrates. Because direct hardware measurement (e.g., RAPL, NVML, smart-plug readings) is not universally available across desktop environments, TriageCore uses a heuristic estimation model grounded in the literature on computational energy accounting. All parameters are configurable in triagecore.toml; defaults are documented below alongside the formulae.

Every estimate is stored in the append-only task ledger together with the estimation_method and measurement_boundary fields so that readers of any derived data can assess the scope and assumptions of each figure.


1. Operational Energy

Operational Energy Formula

$$E = \frac{P \cdot t}{3{,}600{,}000}$$

Symbol Quantity Default
$E$ Energy consumption (kWh)
$P$ Device power draw during inference (W) 300 W
$t$ Task wall-clock duration (s) measured

Rationale for default power assumption.
A value of 300 W is a conservative mid-range estimate for a consumer desktop GPU (e.g., NVIDIA RTX 3070–4090 class) running local inference at moderate load. Users with known hardware specifications should override this value in triagecore.toml using a device profile. The 3,600,000 divisor converts watt-seconds to kilowatt-hours (1 kWh = 3.6 × 10⁶ J).

Implementation reference: SustainabilityEstimator.estimate() in triage_core/sustainability.py, line 25.


2. Operational Carbon Emissions

Operational Carbon Emissions Formula

$$C_{\text{op}} = E \times I_{\text{grid}}$$

Symbol Quantity Default
$C_{\text{op}}$ Operational carbon emissions (gCO₂e)
$E$ Energy (kWh), from §1
$I_{\text{grid}}$ Grid carbon intensity (gCO₂e / kWh) 400 gCO₂e / kWh

Rationale for default grid intensity.
The global average grid carbon intensity is approximately 475 gCO₂e / kWh (IEA, 2023). A default of 400 gCO₂e / kWh is used to represent a modestly cleaner mixed grid (e.g., US average ≈ 386 gCO₂e / kWh, EU average ≈ 255 gCO₂e / kWh). Users in high-renewable regions should supply a location-specific value. Time-of-day variation is not currently modelled; this is noted as a limitation.

Implementation reference: line 26.


3. Indirect Water Footprint

Indirect Water Footprint Formula

$$W = E \times f_{\text{water}}$$

Symbol Quantity Default
$W$ Indirect water consumption (litres)
$E$ Energy (kWh), from §1
$f_{\text{water}}$ Water intensity of electricity generation (L / kWh) 1.5 L / kWh

Rationale.
Electricity generation consumes water through steam-cycle cooling, evaporation at hydroelectric reservoirs, and fuel processing. The default factor of 1.5 L / kWh is derived from global average estimates for a mixed thermoelectric–renewable grid (Meldrum et al., 2013; Grubert & Sanders, 2018). Regional water intensity can vary by more than an order of magnitude; this estimate is conservatively low for grids with significant thermoelectric generation. Direct on-premise cooling water consumption is not included in this boundary.

Measurement boundary: indirect electricity-related water only.

Implementation reference: line 27.


4. Embodied Carbon Allocation

Embodied Carbon Allocation Formula

$$C_{\text{emb}} = C_{\text{device}} \times \frac{t / 3600}{H_{\text{lifetime}}}$$

Symbol Quantity Default
$C_{\text{emb}}$ Embodied carbon allocated to this task (gCO₂e)
$C_{\text{device}}$ Total embodied carbon of the host device (gCO₂e) 300,000 gCO₂e
$t$ Task duration (s) measured
$H_{\text{lifetime}}$ Expected device operational lifetime (hours) 20,000 h

Rationale.
Hardware manufacture accounts for a substantial share of a computing device's lifetime carbon footprint (Gupta et al., 2022). The default of 300,000 gCO₂e (300 kg CO₂e) is a representative figure for a mid-range desktop workstation including GPU (Malmodin & Lundén, 2018; Boavizta consortium estimates). The lifetime of 20,000 hours corresponds to approximately 10 years of average daily use (~5.5 hours/day).

Allocation follows the proportional-use method: the fraction of device lifetime consumed by a task determines the fraction of embodied carbon attributed to it. This method is analogous to the allocation approach used in lifecycle assessment (ISO 14044) and in cloud carbon accounting literature (Lannelongue et al., 2021).

Measurement boundary: embodied carbon of host device only; manufacturing carbon of model weights, training infrastructure, or storage media is not included in this boundary.

Implementation reference: lines 29–30.


5. Per-Accepted-Task Resource Intensity

Per-Accepted-Task Resource Intensity Formula

$$R_{\text{accepted}} = \frac{\sum R_i}{N_{\text{accepted}}}$$

Symbol Quantity
$R_{\text{accepted}}$ Mean resource consumption per accepted task
$\sum R_i$ Total resource consumption across all tasks of type $R$
$N_{\text{accepted}}$ Count of tasks whose outcome is accepted = true

This metric is the primary scientific outcome variable of TriageCore experiments. It deliberately penalises configurations that produce low per-task costs but high rejection or retry rates, because rejected work still consumed real resources without producing accepted software artefacts.

Reported dimensions:

  • kWh per accepted task
  • gCO₂e per accepted task
  • litres of water per accepted task
  • gCO₂e embodied carbon per accepted task
  • tokens (input + output) per accepted task
  • human review minutes per accepted task
  • optional subjective review workload (not_recorded, low, medium, or high)

Human review minutes measure elapsed review time. The optional review_workload label records the reviewer's perceived assessment burden and should be analysed as a subjective ordinal indicator, not as an objective performance metric.

Local-First Benefit Signals

The desktop telemetry dashboard intentionally foregrounds local-first benefit signals because the workbench is also an operator environment. These signals can help the user keep collecting evidence, building artifacts, and noticing when more work is staying on local compute. Current dashboard signals include:

  • accepted yield
  • percent of tasks routed through local-first runners
  • count of accepted local-first tasks
  • percent of tasks that did not require mandatory human review

These are motivational and operational indicators, not standalone proof of environmental savings. Reports, papers, and methodology artifacts should describe them as benefit or avoidance signals unless a study defines a baseline comparison, such as local-first routing versus a remote-only workflow using the same benchmark fixture set.

Context Budgeting And Context Packs

TriageCore estimates context cost before dispatch using a simple advisory planner. The planner classifies context items as required, helpful, optional, or excluded, selects a token budget from the runner or benchmark category, and writes a JSON context-pack artifact linked to the task ledger.

The current estimator uses an approximate four-characters-per-token heuristic. This is intentionally conservative and reproducible, but it is not a substitute for exact backend token usage. Exact backend usage, when available, should remain the preferred measurement for final token accounting. Context packs answer a different question: what did TriageCore intend to include, exclude, summarize, or preserve before the model call?

Context budget status (within_budget or over_budget) is advisory in this phase. Over-budget context produces a warning and evidence, not automatic blocking. Future studies may test whether enforcement improves tokens per accepted task without harming validator pass rate, handoff behavior, or review workload.


6. Model And Backend Comparison

Model/backend comparison studies use the same benchmark fixture set across each candidate configuration and tag all evidence with a shared study_id plus a unique run_id for each backend/model pair. Reports group evidence by supervision lane, backend, and backend/model so that supervised workflows, runtime-adapter differences, and model differences are not confused with one another.

Comparison runs should use:

  • identical benchmark fixtures
  • identical timeout settings unless timeout is the experimental variable
  • explicit backend type, base URL when applicable, and model identifier
  • separate run_id values for every backend/model pair
  • the combined benchmark-report --study-id <study> output for interpretation
  • the By Supervision section when local-only and supervised outcomes are mixed

Expected destructive-task handoff is treated as correct safety behavior. A configuration should only be preferred when it improves accepted outcomes without increasing unexpected handoffs, validator failures, or subjective review burden.


7. Supervised Hybrid Workflows

TriageCore distinguishes local-only execution from supervised hybrid workflows. A local draft, worker-council result, benchmark run, or pipeline attempt may be reviewed by Codex, Antigravity, Gemini, or a human reviewer before it is treated as accepted work. These reviews are recorded as supervisor_reviewed events rather than merged into the original local execution event.

This separation matters because supervision changes the workflow being studied. A Codex-reviewed patch and an Antigravity-supervised IDE implementation may use the same local model output, but they also add different review tools, reasoning contexts, token costs, and human oversight patterns. Reports should therefore label supervised outcomes separately from local-only outcomes whenever they are used as scientific evidence.

Codex And Antigravity Role Separation

For day-to-day project development, TriageCore treats Antigravity and Codex as different supervisory lanes with different strengths. Antigravity is the high-throughput implementation lane: it is well suited to IDE-native coordination, larger draft implementations, local model pipeline experiments, and rapid backlog movement. Codex is the credibility and stabilization lane: it is used to reconcile changes against the repository, strengthen methodology and documentation, check evidence boundaries, prepare paper-facing language, and run stability checks before work is treated as publication-ready.

This role separation does not imply that Codex-processed documentation is automatically correct or that Antigravity-generated implementation is automatically accepted. Both lanes remain subject to human review, ledger evidence, test results, and explicit uncertainty labels. The separation exists to reduce workflow confusion: Antigravity helps produce draft volume, while Codex helps convert draft work into cautious, reproducible, falsifiable project artifacts.

Supervisor review fields include the supervising tool, model, profile, decision, notes, linked artifact path, and estimated supervisor input/output tokens when exact usage is not available. Estimated token fields should be interpreted as approximate evidence only.

Benchmark reports summarize supervisor reviews under the same study_id and run_id filters as the benchmark evidence. The Supervisor Reviews table reports review counts, decision counts, and estimated supervisor token totals by tool. Supervisor token values remain manual estimates unless a supervisor tool log or API exposes exact usage data.

This boundary is intentionally conservative: imported exact usage, imported estimates, and manual estimates are labelled separately so claims remain verifiable, reproducible, and falsifiable.


8. Default Parameter Summary

Parameter Symbol Default Unit Override key in triagecore.toml
Device power draw $P$ 300 W sustainability.default_watts
Grid carbon intensity $I_{\text{grid}}$ 400 gCO₂e / kWh sustainability.grid_intensity_gco2e_per_kwh
Water intensity $f_{\text{water}}$ 1.5 L / kWh sustainability.water_intensity_l_per_kwh
Device embodied carbon $C_{\text{device}}$ 300,000 gCO₂e sustainability.device_embodied_gco2e
Device lifetime $H_{\text{lifetime}}$ 20,000 hours sustainability.device_lifetime_hours

9. Estimation Caveats and Limitations

  1. Power draw is assumed, not measured. Direct measurement via RAPL (Intel/AMD), NVML (NVIDIA), or a smart plug would substantially improve accuracy. The current model assumes constant load at the configured wattage for the full task duration; idle periods within a task are not accounted for.

  2. Grid intensity is static. Carbon intensity varies by time of day and season. Tools such as ElectricityMaps or the WattTime API could provide real-time intensity values as a future enhancement.

  3. Water estimates are regional-average proxies. The factor of 1.5 L / kWh may underestimate intensity for coal-heavy grids or overestimate for predominantly hydro/wind grids.

  4. Embodied carbon defaults are order-of-magnitude estimates. Actual figures depend on hardware manufacturer, manufacturing region, and device class. Boavizta device profiles or manufacturer-published product carbon footprint disclosures should be used where available.

  5. Training carbon is out of scope. The embodied carbon of the model weights themselves (i.e., the compute used to train the LLM) is not attributed to inference tasks in this version. This is a known boundary choice, consistent with operational-boundary carbon accounting, and should be stated explicitly in any published results.

  6. All estimates are labelled as estimates. Every ledger record includes "estimation_method": "heuristic_profile_v1" and "measurement_boundary": "local operational estimate plus optional embodied amortisation" to signal this scope to downstream consumers of the data.


10. Execution Hardware Specification

For the comparison study of local model execution and specialist councils (Study 002), the benchmarking environment was standardized on a host workstation with the following hardware specifications:

  • Host System: Alienware m18 R1 AMD Laptop
  • Processor (CPU): AMD Ryzen 9 7845HX with Radeon Graphics (12 physical cores, 24 threads, AVX/AVX2 support)
  • System Memory (RAM): 32 GB DDR5 RAM (33,487,876,096 bytes)
  • Dedicated Graphics (GPU): NVIDIA GeForce RTX 4070 Laptop GPU (Discrete, Compute Capability 8.9, 8 GB VRAM / 8,585,216,000 bytes)
  • Operating System: Windows 11 Pro 64-bit (Build 26200)

This system configuration is representative of developer-class workstations where local model offloading is actively deployed to protect the cloud compute budget.


11. References

Grubert, E., & Sanders, K. T. (2018). Water use in the United States energy system: A national assessment and unit process inventory of water consumption and withdrawals. Environmental Science & Technology, 52(11), 6695–6703. https://doi.org/10.1021/acs.est.8b00139

Gupta, U., Kim, Y. G., Lee, S., Tse, J., Lee, H. H. S., Wei, G.-Y., Brooks, D., & Wu, C.-J. (2022). Chasing carbon: The elusive environmental footprint of computing. IEEE Micro, 42(4), 37–47. https://doi.org/10.1109/MM.2022.3163226

International Energy Agency. (2023). Electricity 2024: Analysis and forecast to 2026. IEA. https://www.iea.org/reports/electricity-2024

Lannelongue, L., Grealey, J., & Inouye, M. (2021). Green algorithms: Quantifying the carbon footprint of computation. Advanced Science, 8(12), 2100707. https://doi.org/10.1002/advs.202100707

Malmodin, J., & Lundén, D. (2018). The energy and carbon footprint of the global ICT and E&M sectors 2010–2015. Sustainability, 10(9), 3027. https://doi.org/10.3390/su10093027

Meldrum, J., Nettles-Anderson, S., Heath, G., & Macknick, J. (2013). Life cycle water use for electricity generation: A review and harmonization of literature estimates. Environmental Research Letters, 8(1), 015031. https://doi.org/10.1088/1748-9326/8/1/015031