Repository navigation
Expand file tree
/
Copy pathexample.mdl
More file actions
74 lines (73 loc) · 3.42 KB
/
Copy pathexample.mdl
File metadata and controls
74 lines (73 loc) · 3.42 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
7 Number of Modes X
7 Number of Modes Y
237 X-Period, nm
237 Y-Period, nm
560 Wavelength, nm
0 Pol State, deg
0 Pol phase, def
0 AngleN, deg (Cover, Plane Base)
0 AngleP, deg (Cover, Plane Base)
1 Number of Layers
1 0 Eps.Re; Eps.Im; Cover; Material: Air (Special Formula)
100 1 Layer[1]: Thickness, nm; Number of Pillars
1 0 Base Eps.Re; Eps.Im; Material: Air (Special Formula)
1 0 2 Eps.Re; Eps.Im; Npoints of Pillar[1]; Material: Silicon (Table)
0.2890295358649789 0.2890295358649789 x[1]/(X-Period); y[1]/(Y-Period)
0.7109704641350211 0.7109704641350211 x[2]/(X-Period); y[2]/(Y-Period)
1 0 Eps.Re; Eps.Im; Substrate;; Material: Fused Silica (Sellmeier)
Settings For FMM Crossed
true UsingNF
false UsingSmooth
0 SmoothStart
0 SmoothWidth
true Background Calculation
false Memory Consumption
false Calculation Direction From Substrate to Cover
Y Number of Modes Correction
3 Calculation Priority
true Cover Diffraction Orders
false Substrate Diffraction Orders
0 0 X,Y Cover Order
0 0 X,Y Substrate Order
0 0 MinMax X Cover Order
0 0 MinMax Y Cover Order
0 0 MinMax X Substrate Order
0 0 MinMax Y Substrate Order
P Scanning Output Format: Power; Amplitude (Re,Im); Amplitude (Mod,Ph)
true Diffraction Angle
%10.5g Decimal Digits Format
WaveL String of Scanning Parameter
5 Row Scanning Parameter
100 Nubmber of Column Points -1
0 0 Range of Scanning AngleN
0 0 Range of Scanning AngleP
137 137 Range of Scanning X-Period
137 137 Range of Scanning Y-Period
400 700 Range of Scanning Wavelength
0 0 Range of Scanning RowVar
0 0 Range of Scanning ColVar
38.5 38.5 Range of Scanning Thickness of Layer[1]
1 Layer Index
false Advanced Options
false Field Calculation
true Automatically Starts Second Stage
100 Nubmber of Points -1 for NPFx
100 Nubmber of Points -1 for NPFy
100 Nubmber of Points -1 for NPFz
-1 2D Field Component
M Field Output Format: Power Flow; Amplitude (Re,Im); Amplitude (Mod,Ph)
%10.5g Decimal Digits Format
0 Scanning Direction
0 Units Along X
0 1 Range of Scanning X Direction
0 1 Range of Scanning Y Direction
0 82 Range of Scanning Z Direction
0 Fixed X
0 Fixed Y
0 Fixed Z
0 Graph Index for X-axis
1 Graph Index for Y-axis
2 Graph Index for Z-axis
0 Polarization Type (Any, Hy=0, Ey=0, Hx=0, Ex=0)
false Output Polarizer
0 Polarizer Angle, deg