Klik Add IED, lalu pilih IP live atau file SCL.
Gunakan Discover IED by IP untuk relay yang dapat dijangkau. Gunakan Open SCL / CID / ICD untuk memeriksa model vendor atau project secara offline; IID dan SCD juga didukung oleh workflow SCL.
diff --git a/docs/asset-provenance-manifest.json b/docs/asset-provenance-manifest.json index d057842fb..21b6c4334 100644 --- a/docs/asset-provenance-manifest.json +++ b/docs/asset-provenance-manifest.json @@ -3,10 +3,10 @@ "audited_repository": "masarray/arsas", "audited_commit": "45838496e5dd289b42fbb731a6cafd8cd3547c32", "audited_date": "2026-10-25", - "scope": "All Git-tracked binary visual/font assets (.png, .jpg, .jpeg, .webp, .ico, .svg, .ttf, .otf, .woff2, .gif), including 16 verified v1.6.42 operator PNG/WebP screenshot assets.", + "scope": "All Git-tracked binary visual/font assets, including 16 operator-approved v1.6.42 PNG/WebP captures and one additional authentic cropped v1.6.42 Connect to IED dialog WebP.", "disclaimer": "Inventory and Git identity only. This manifest does not certify originality, license clearance, or freedom from resemblance. Manual origin/rights/content review remains required where disposition says so.", - "tracked_asset_count": 81, - "unique_blob_count": 58, + "tracked_asset_count": 82, + "unique_blob_count": 59, "files": [ { "path": "Assets/app-icon-256.png", @@ -289,6 +289,25 @@ "duplicate_of": null, "review_status": "origin-rights-and-visual-similarity-review-required" }, + { + "path": "landing/assets/screenshots/arsas-add-ied-connect-dialog-v1.6.42.webp", + "blob_sha": "82221972ff30404603fa1b7a5256f16b039e38f8", + "size_bytes": 5194, + "duplicate_of": null, + "source_filename": "image(20261025-142302).png", + "source_sha256": "29e711addbc31f553ae936cdbe8a0d03f2ceb70b0579d823d0d4a3766da2a84a", + "crop_rectangle_xyxy": [ + 657, + 275, + 1035, + 597 + ], + "dimensions": [ + 378, + 322 + ], + "review_status": "authentic v1.6.42 operator-provided Connect dialog crop; user explicitly approved public screenshot privacy 2026-10-25" + }, { "path": "landing/assets/screenshots/arsas-alarm-annunciator-v1.6.40.webp", "blob_sha": "29b9b3866ce8b29b401df8ffde0cd9239b623b5d", diff --git a/landing/assets/screenshots/arsas-add-ied-connect-dialog-v1.6.42.webp b/landing/assets/screenshots/arsas-add-ied-connect-dialog-v1.6.42.webp new file mode 100644 index 000000000..82221972f Binary files /dev/null and b/landing/assets/screenshots/arsas-add-ied-connect-dialog-v1.6.42.webp differ diff --git a/landing/templates/id.html b/landing/templates/id.html index cbbfc54be..ed18d4845 100644 --- a/landing/templates/id.html +++ b/landing/templates/id.html @@ -108,14 +108,14 @@
Dua gambar dialog konfigurasi awal adalah contoh historis v1.6.40; gambar IED Browser di bawah berasal dari capture asli operator v1.6.42.
Seluruh gambar onboarding menampilkan aplikasi asli v1.6.42, termasuk crop autentik dialog Connect to IED.


Gunakan Discover IED by IP untuk relay yang dapat dijangkau. Gunakan Open SCL / CID / ICD untuk memeriksa model vendor atau project secara offline; IID dan SCD juga didukung oleh workflow SCL.


ARSAS terhubung melalui IEC 61850 MMS pada port 102, membaca identity IED yang sebenarnya, lalu membangun live model. Jika memilih file SCL, ARSAS membuka configured model tersebut tanpa membuat koneksi live.
The first two setup-dialog images are historical v1.6.40 examples; the IED Browser example below is an actual v1.6.42 operator capture.
All onboarding images now show the actual v1.6.42 application, including an authentic crop of the current Connect to IED dialog.


Use Discover IED by IP for a reachable relay. Use Open SCL / CID / ICD to inspect a vendor or project model offline; IID and SCD are supported by the SCL workflow too.


ARSAS connects over IEC 61850 MMS on port 102, reads the real IED identity and builds its live model. If you chose an SCL file, ARSAS opens that configured model without making a live connection.
ARSAS adalah tester IEC 61850 untuk Windows. Hubungkan relay lewat IP pada network test yang berwenang Anda gunakan, atau buka file engineering SCL—ICD, CID, IID maupun SCD—untuk memeriksa configured model secara offline.
Langkah 1 dan 2 menggunakan gambar dialog konfigurasi historis v1.6.40. Langkah 3 menggunakan IED Browser asli v1.6.42. Tampilannya dapat berbeda antarversi.

Klik Add IED. Pilih Discover IED by IP untuk relay live. Pilih Open SCL / CID / ICD untuk model engineering offline; workspace SCL juga menerima IID dan SCD.

Pertahankan MMS port 102 kecuali project menetapkan endpoint lain. Pilih Connect & Discover; ARSAS membaca identity IED yang sebenarnya, DataSet, RCB, dan live model melalui jalur Smart Discovery produksi.
Semua screenshot menampilkan aplikasi asli v1.6.42. Langkah 2 memakai crop dialog Connect to IED dari screenshot operator.

Pilih Device Explorer, lalu klik Add IED di panel kiri. Pada v1.6.42 dialog Connect to IED langsung terbuka. File SCL diimpor melalui workspace SCL secara terpisah.

Isi alamat IP pada field empat oktet, lalu klik Connect. Buka Advanced settings bila perlu mengubah detail koneksi seperti port MMS default 102. ARSAS kemudian mencoba koneksi dan discovery IED.

Pilih Static DataSet untuk jalur cepat report-ready, atau Select Signals untuk pemilihan manual. Review value, quality, dan timestamp di Live Monitor. Gunakan Command Dock hanya untuk control object tervalidasi dengan prosedur test yang disetujui.
Tiga langkah di atas adalah jalur sukses pemula. Gunakan checklist yang lebih dalam ini sebelum FAT, GOOSE, SMV, file transfer atau active control pada pekerjaan lapangan.
ARSAS is a Windows IEC 61850 tester. Connect a relay by IP on an authorized test network, or open an SCL engineering file—ICD, CID, IID or SCD—to inspect the configured model offline.
Steps 1 and 2 use archived v1.6.40 setup-dialog examples. Step 3 shows the current v1.6.42 IED Browser. The UI may differ between those two source versions.

Click Add IED. Select Discover IED by IP for a live relay. Select Open SCL / CID / ICD for an offline engineering model; the SCL workspace also accepts IID and SCD.

Keep MMS port 102 unless the project explicitly specifies another endpoint. Select Connect & Discover; ARSAS reads the real IED identity, DataSets, RCBs and live model through the production Smart Discovery path.
All screenshots show the actual v1.6.42 application. Step 2 is cropped from the operator-provided Connect to IED screenshot.

Select Device Explorer, then click Add IED in the left rail. In v1.6.42 the Connect to IED dialog opens directly. SCL files are handled separately by the SCL import workspace.

Enter the address in the four-octet IP field, then select Connect. Open Advanced settings only if connection details such as the default MMS port 102 need changing. ARSAS attempts IED connection and discovery.

Choose Static DataSet for a fast report-ready path, or Select Signals for manual selection. Review value, quality and timestamp in Live Monitor. Use the Command Dock only for validated control objects under an approved test procedure.
The three-step path above is the beginner success path. Use this deeper checklist before FAT, GOOSE, SMV, file transfer or active control in field work.