From 0ba262ea70a30d3b5382e742c581519e857fecde Mon Sep 17 00:00:00 2001 From: Tim-Oliver Husser Date: Wed, 25 Nov 2026 18:00:37 +0100 Subject: [PATCH] Log the readings a warm-up step used and why the warm-up ended The progress line on close showed sensor and power read again after the step, which could differ from the reading the step was planned with. It now shows the reading the step used. The done line says whether the setpoint reached the off temperature or the cooler was idle, with the readings. RampStep gains an idle field. Co-Authored-By: Claude Opus 5.5 --- CHANGELOG.md | 6 ++++++ pyobs/mixins/coolingramp.py | 37 +++++++++++++++++++++----------- pyobs/utils/coolingramp.py | 7 ++++-- tests/mixins/test_coolingramp.py | 24 +++++++++++++++------ tests/utils/test_coolingramp.py | 8 ++++++- 5 files changed, 60 insertions(+), 22 deletions(-) diff --git a/CHANGELOG.md b/CHANGELOG.md index 5224c332e..892a094e9 100644 --- a/CHANGELOG.md +++ b/CHANGELOG.md @@ -9,6 +9,12 @@ Entries for 2.6.0 to 2.14.0 were generated from commit subjects. Older entries w ## [Unreleased] +### Changed + +- The warm-up progress line on close shows the sensor temperature and power the last step was planned with, + instead of reading them again after the step. The done line says why the warm-up ended (setpoint reached, or + cooler idle, with the readings). `RampStep` has a new field `idle`. + ## [2.29.1] - 2026-11-25 ### Changed diff --git a/pyobs/mixins/coolingramp.py b/pyobs/mixins/coolingramp.py index 4e719c321..a613ae7a9 100644 --- a/pyobs/mixins/coolingramp.py +++ b/pyobs/mixins/coolingramp.py @@ -86,6 +86,9 @@ def __init__( self._cooling_commanded: float | None = None self._cooling_event = asyncio.Event() self._cooling_failures = 0 + # sensor temperature and power the last warm-up step was planned with, and how the last ramp ended + self._cooling_reading: tuple[float | None, int | None] = (None, None) + self._cooling_end: str | None = None self._cooling_task = self.add_background_task(self._cooling_ramp_loop, True) # type: ignore[attr-defined] @@ -197,6 +200,7 @@ async def _cooling_warm_up(self, timeout: float) -> None: """Runs the warm-up ramp to its end. Logs when it starts, about every _WARMUP_LOG_INTERVAL seconds while it runs, and when it is done, so the log shows why the module takes long to stop.""" start = time.monotonic() + self._cooling_reading, self._cooling_end = (None, None), None delay = await self._cooling_tick() if self._cooling_target is None: return # cooler was off already, or switched off in the first step @@ -213,25 +217,19 @@ async def _cooling_warm_up(self, timeout: float) -> None: delay = await self._cooling_tick() now = time.monotonic() if self._cooling_target is not None and now >= next_log: - await self._cooling_log_warm_up(start + timeout - now) + self._cooling_log_warm_up(start + timeout - now) next_log = now + _WARMUP_LOG_INTERVAL - log.info("Warm-up done after %s, cooling is off.", _duration(time.monotonic() - start)) + end = f", {self._cooling_end}" if self._cooling_end else "" + log.info("Warm-up done after %s%s, cooling is off.", _duration(time.monotonic() - start), end) - async def _cooling_log_warm_up(self, left: float) -> None: - # only for the log, the next tick reports a real problem - try: - sensor = await self._get_sensor_temperature() - except Exception: - sensor = None - try: - _, _, power = await self._get_cooling_hardware() - except Exception: - power = None + def _cooling_log_warm_up(self, left: float) -> None: + """Logs the progress, with the readings the last step was planned with.""" + sensor, power = self._cooling_reading log.info( "Warming up: setpoint %s, sensor %s, power %s, up to %s left.", _temperature(self._cooling_commanded), _temperature(sensor), - "unknown" if power is None else f"{power} %", + _power(power), _duration(max(0.0, left)), ) @@ -303,6 +301,15 @@ async def _cooling_tick(self) -> float | None: sensor = await self._get_sensor_temperature() _, _, power = await self._get_cooling_hardware() step = self._cooling_ramp.next_step(commanded, enabled, setpoint, sensor, power) + if not enabled: + self._cooling_reading = (sensor, power) + if step.done: + self._cooling_end = ( + f"cooler idle at setpoint {_temperature(commanded)}, sensor {_temperature(sensor)}, " + f"power {_power(power)}" + if step.idle + else f"setpoint at {_temperature(commanded)}" + ) if step.write: await self._set_cooling_hardware(step.enabled, step.setpoint) self._cooling_commanded = step.setpoint @@ -321,6 +328,10 @@ def _temperature(value: float | None) -> str: return "unknown" if value is None else f"{value:.1f} °C" +def _power(value: int | None) -> str: + return "unknown" if value is None else f"{value} %" + + def _duration(seconds: float) -> str: return f"{seconds:.0f} s" if seconds < 90 else f"{seconds / 60:.0f} min" diff --git a/pyobs/utils/coolingramp.py b/pyobs/utils/coolingramp.py index 6b5b0d28d..71db8d3f5 100644 --- a/pyobs/utils/coolingramp.py +++ b/pyobs/utils/coolingramp.py @@ -29,6 +29,7 @@ class RampStep: setpoint: Setpoint to write, None if the cooler is to be switched off. done: Whether the ramp has reached its target after this step. delay: Seconds to wait before asking for the next step (0 if done). + idle: Whether a warm-up stopped early because the cooler was idle. """ write: bool @@ -36,6 +37,7 @@ class RampStep: setpoint: float | None done: bool delay: float + idle: bool = False class CoolingRamp: @@ -148,9 +150,10 @@ def next_step( if not enabled: idle = sensor is not None and commanded >= sensor + IDLE_MARGIN and (power is None or power == 0) self._idle_count = self._idle_count + 1 if idle else 0 - if self._idle_count >= self.idle_steps or commanded >= goal or self.rate_warm is None: + stop_idle = self._idle_count >= self.idle_steps and commanded < goal + if stop_idle or commanded >= goal or self.rate_warm is None: self._idle_count = 0 - return RampStep(write=True, enabled=False, setpoint=None, done=True, delay=0.0) + return RampStep(write=True, enabled=False, setpoint=None, done=True, delay=0.0, idle=stop_idle) else: self._idle_count = 0 if commanded == goal: diff --git a/tests/mixins/test_coolingramp.py b/tests/mixins/test_coolingramp.py index 08e887ccd..8c4aa5c1f 100644 --- a/tests/mixins/test_coolingramp.py +++ b/tests/mixins/test_coolingramp.py @@ -313,8 +313,10 @@ async def test_close_with_warmup_logs_start_progress_and_end( await camera.close() lines = [r.getMessage() for r in caplog.records if r.name == "pyobs.mixins.coolingramp"] assert lines[0] == "Warming up from -9.0 °C towards -8.0 °C before closing, may take up to 30 s." - assert lines[1] == "Warming up: setpoint -8.0 °C, sensor -8.5 °C, power 80 %, up to 30 s left." - assert lines[-1].startswith("Warm-up done after ") and lines[-1].endswith("cooling is off.") + # sensor and power are the ones the step was planned with, read before the setpoint went to -8 + assert lines[1] == "Warming up: setpoint -8.0 °C, sensor -9.5 °C, power 80 %, up to 30 s left." + assert lines[-1].startswith("Warm-up done after ") + assert lines[-1].endswith(", setpoint at -8.0 °C, cooling is off.") assert len(lines) == 3 @@ -328,13 +330,23 @@ async def test_close_with_cooler_already_off_logs_no_warmup(caplog: pytest.LogCa @pytest.mark.asyncio -async def test_warmup_progress_survives_failing_reads(caplog: pytest.LogCaptureFixture) -> None: +async def test_close_with_idle_cooler_logs_why_it_stopped_early(caplog: pytest.LogCaptureFixture) -> None: + camera = make_camera(cooling_rate_warm=600.0, cooling_close_timeout=30.0) + camera._cooling = camera._cooling._replace(temperatures={"CCD": -8.0, "Back": 3.0}, power=0) # setpoint -10 + with caplog.at_level("INFO", logger="pyobs.mixins.coolingramp"): + await camera.close() + lines = [r.getMessage() for r in caplog.records if r.name == "pyobs.mixins.coolingramp"] + # idle from -7 (sensor + 1) on, off after the third idle reading at -5 + assert lines[-1].endswith(", cooler idle at setpoint -5.0 °C, sensor -8.0 °C, power 0 %, cooling is off."), lines[ + -1 + ] + + +def test_warmup_progress_without_readings_says_unknown(caplog: pytest.LogCaptureFixture) -> None: camera = make_camera() camera._cooling_commanded = -12.0 - camera._get_sensor_temperature = AsyncMock(side_effect=RuntimeError("SDK error")) # type: ignore[method-assign] - camera._get_cooling_hardware = AsyncMock(side_effect=RuntimeError("SDK error")) # type: ignore[method-assign] with caplog.at_level("INFO", logger="pyobs.mixins.coolingramp"): - await camera._cooling_log_warm_up(840.0) + camera._cooling_log_warm_up(840.0) msg = "Warming up: setpoint -12.0 °C, sensor unknown, power unknown, up to 14 min left." assert caplog.records[-1].getMessage() == msg diff --git a/tests/utils/test_coolingramp.py b/tests/utils/test_coolingramp.py index a4f9a7bc2..1bbc6f54f 100644 --- a/tests/utils/test_coolingramp.py +++ b/tests/utils/test_coolingramp.py @@ -71,7 +71,13 @@ def test_disable_stops_early_when_sensor_stops_following() -> None: assert ramp.next_step(6.0, False, None, sensor=5.0, power=0).setpoint == 7.0 assert ramp.next_step(7.0, False, None, sensor=5.0, power=0).setpoint == 8.0 step = ramp.next_step(8.0, False, None, sensor=5.0, power=0) - assert step.done and step.enabled is False and step.setpoint is None + assert step.done and step.enabled is False and step.setpoint is None and step.idle + + +def test_disable_at_the_end_point_is_not_an_idle_stop() -> None: + ramp = CoolingRamp(rate_warm=1.0, off_temperature=20.0, idle_steps=1) + step = ramp.next_step(20.0, False, None, sensor=5.0, power=0) + assert step.done and step.enabled is False and not step.idle def test_disable_needs_idle_readings_in_a_row() -> None: