The /state interface — bring your own exporter

The surplus-controller consumes exactly one input: a small JSON document served by the energy-exporter at GET /state (default port 9121). It does not know or care what hardware produced the numbers. This document is the contract. If you serve it, Sunsteer can control your heat pump — regardless of meter brand or programming language.

Schema (version 1)

{
  "schema": 1,
  "surplus_w": 2480.5,
  "import_w": 0.0,
  "export_w": 2480.5,
  "shm_age_s": 0.8,
  "shelly_on": true,
  "shelly_power_w": 0.0,
  "shelly_reachable": true,
  "production_w": 3100.0
}
Field Required Meaning
schema yes Contract version. Currently 1; bumped only on breaking changes.
surplus_w yes Grid export minus import in watts. Positive = exporting (surplus available), negative = importing.
import_w yes Current grid import, W (≥ 0).
export_w yes Current grid export, W (≥ 0).
shm_age_s yes Seconds since the last real meter reading, or null if none was ever received. See freshness semantics below.
shelly_on no Last polled relay state.
shelly_power_w no Power measured by the relay, W. With the usual SG-Ready signal wiring this is 0.0 — see hardware.md.
shelly_reachable no Whether the last relay poll succeeded.
production_w no Current inverter AC production, W (only with inverter telemetry enabled).

Unknown extra fields are ignored by the controller — you may add your own.

Freshness semantics (the safety-critical part)

shm_age_s is the controller's lifeline. The rules an exporter MUST follow:

  1. Only a real meter reading may refresh the timestamp behind shm_age_s. Never refresh it from relay polls, inverter polls, retries, cache hits, or "the process is still alive" heartbeats. If the meter goes silent, shm_age_s must grow.
  2. The controller treats a reading older than its STATE_STALE_SECONDS (default 30 s) — or an unreachable /state, or shm_age_s: null — as blind and fails safe: after a short grace period the heat-pump relay is switched OFF.
  3. Readings should arrive at a cadence comfortably faster than the staleness limit. The SMA Sunny Home Manager broadcasts roughly every second; anything under ~10 s works with the default limits.

Faking freshness defeats the central safety mechanism of the system. Don't.

Conventions

  • Power unit is watts as JSON numbers; sign convention for surplus_w is export - import.
  • The endpoint must answer fast (< 1 s) and must not block on the hardware — serve the last known reading and let shm_age_s reflect its age.
  • Any non-200 response or connection error counts as blind (see rule 2), which is the correct behaviour when your exporter is down.

Wiring it up

Point the controller at your exporter:

EXPORTER_STATE_URL=http://my-exporter:9121/state

Everything else (relay control via SHELLY_URL, forecast, thresholds) stays unchanged. The built-in mock driver (METER_DRIVER=mock) is a working reference implementation of this contract — readable in services/energy-exporter/src/drivers/mock.py together with services/energy-exporter/src/state_server.py.