Show a visual charging indicator in the telemetry UI when the board is connected to a wall charger.
state_compat value 14 exists in Refloat for when the board enters a charging state. Checked via v.state & 0xf === 14.
Result: Never triggered. The board always reports FAULT_STARTUP (state 11) when stationary and not riding, including when the charger is plugged in. State 14 requires Refloat to actively detect and enter charging mode, which doesn't happen on this hardware.
When regen-braking during riding, current flows into the battery through the VESC motor controller. This shows as a negative batteryCurrent. However, this is a riding indicator ("braking hard"), not "wall charger is plugged in."
Result: Always 0.0 when stationary (charger or not). Not useful for detecting wall charging.
Refloat mode 4 appends two extra fields at bytes 55–58 of the COMMAND_GET_ALLDATA response:
[55–56]int16 / 10→charging.current(A)[57–58]int16 / 10→charging.voltage(V)
These come from Refloat's charging subsystem (src/charging.h), which is designed to detect an external charger connected to a dedicated charging circuit wired through or sensed by the VESC.
We wired up the full stack for mode 4:
- Android native parser extended to read bytes 55–58
RefloatTelemetrydata class extended withchargingCurrent: Double?/chargingVoltage: Double?TelemetryEventTS interface extendedRefloatValuesTS interface extendedparseGetAllDatainrefloat.tsextended- Poll mode changed from
2→4
Confirmed working via logcat:
parseGetAllData: mode=4 payloadSize=59
parseGetAllData: chargingCurrent=0.0 chargingVoltage=0.0
Result: Always 0.0. The charger on this hardware connects directly to the battery, bypassing the VESC motor controller entirely. The VESC has no current sensor on the charging path, so d->charging.current is always zero. Refloat's charging subsystem has nothing to measure.
Hardware topology: The wall charger is wired directly to the battery pack, not through the VESC. The VESC only sees current that flows through its motor controller (drive current + regen). The charger is electrically invisible to the VESC and therefore to Refloat.
Wall charger ──────► Battery
│
VESC ──► Motor
- BMS CAN data: Some BMSs expose charging current/voltage over CAN. If the BMS is connected to the VESC's CAN bus, Refloat could potentially read this and populate
d->charging.current. This would require BMS CAN support in both the BMS firmware and Refloat. - Dedicated charge-detect pin: Some boards wire a GPIO to the VESC that goes high when a charger is plugged in. Refloat can read this and set state 14 (CHARGING). This board does not have this wiring.
- Voltage trend heuristic: Detect rising battery voltage over a short window while the board is stationary. Rejected — considered a hack; not reliable across different battery states.
All mode 4 changes were reverted. Poll mode is back to 2. No charging indicator is shown in the UI. The mode 4 infrastructure can be re-added when a reliable data source becomes available.