Safety Warnings & Thresholds

index | tune

Refloat / VESC firmware runs the real-time safety loop on the controller — pushbacks, faults, and voltage cutoffs — independent of the app. This is a reference for those warnings and their default thresholds.

Pushbacks (nose lifts to warn the rider)

Warning Param Default Meaning
Duty-cycle push tiltback_duty 0.80 (80%) Approaching duty limit. Max VESC duty is 95%, not 100% — pushing past 95% nosedives.
High-voltage push tiltback_hv 64.5 V Overcharge / regen (braking or downhill on a full pack). Rule of thumb: 4.3 V × cells (15s → 64.5 V).
Low-voltage push tiltback_lv 45.0 V Battery low — stop riding. Rule of thumb: 3.0 V × cells (15s → 45 V). Always respect it.

Each pushback has an _angle (nose-up target) and _speed (how fast the nose lifts). Fast pushback is itself hazardous — keep _speed conservative (HV/LV default 1 °/s, duty 3 °/s).

Low-voltage ordering: the motor-config Voltage Cutoff Start/End should sit below tiltback_lv. LV pushback is the "stop now" notice; the voltage cutoffs are last-resort battery protection. If the cutoffs rise above LV pushback, the warning is defeated.

Voltage units (firmware-dependent): since Refloat 1.2 on VESC 6.05+, tiltback_lv / tiltback_hv support per-cell values (defaults 3.0 / 4.3) while legacy pack totals remain valid. Refloat interprets values below 10 V as per-cell and larger values as pack totals. On 6.02 all values are pack totals (e.g. 3.0 × 15 = 45 V). The config-safety detector follows the same rule. When the firmware version is unknown/unparseable, or a pack total lacks the configured series count, the LV/HV rules are skipped rather than guessed.

Fault disengagement (board turns off)

Fault Param Default Trigger
Pitch fault fault_pitch 20° Nose tips past this angle.
Roll fault fault_roll 45° Excessive roll.
Footpad switch fault fault_adc1 / fault_adc2 2.0 V Sensor zone reads below this → "foot off". 0 disables the switch.
Half-state fault ERPM fault_adc_half_erpm ~200 Speed above which a single footpad off counts as a fault.

App note: the footpad UI resolves engagement from fault_adc1 / fault_adc2 through Board Config Values. The footpad control screen also lists the board's own fault setup read-only (engage voltages, half/full switch delays, fault_adc_half_erpm, Posi, moving faults, Darkride, Quickstop). The live indicator still shows engagement per zone only — one footpad off below fault_adc_half_erpm is tolerated by the board, and the app does not distinguish that case.

fault_delay_* params add debounce — keep them small. fault_moving_fault_disabled and fault_darkride_enabled weaken fault protection and need correct speed calibration; default off.

Advanced / expert-only

Feature Param Default Notes
Surge surge_angle 0 Off by default. Riding near the duty limit is dangerous — not for beginners.
Surge start surge_duty_start 0.88 Only when surge enabled; higher = riskier.
Remote throttle remote_throttle_current_max 0 A Off by default. An idling remote must sit at 0% or it drains the pack.

Live remote-tilt clamp

The remote-tilt (nose Move) value is clamped to 20..80 before the command packet is built — a transient runtime command, not a persistent config write.