VESC Protocol

index | architecture | refloatAlldata

Packet framing

Short packet (payload ≤ 255 bytes):

[0x02] [len: 1B] [payload: N bytes] [crc_hi] [crc_lo] [0x03]

CRC: CRC-16/XMODEM, poly=0x1021, init=0x0000, big-endian.

The reassembler (src/vesc/reassembler.ts) handles packets split across multiple BLE MTU chunks.

Command IDs (subset)

Name ID Notes
COMM_FW_VERSION 0x00 Handled by ESP32 locally. Use as connectivity ping — it generates a response.
COMM_GET_VALUES 0x04 Standard motor telemetry. Must be CAN-forwarded on ADV2.
COMM_ALIVE 0x1E Keepalive. No response — useless as a connectivity test.
COMM_FORWARD_CAN 0x22 Prefix wrapper: [0x22, canId, <actual command>]
COMM_CUSTOM_APP_DATA 0x24 Refloat package commands. Must be CAN-forwarded.
COMM_PING_CAN 0x3E ESP32 discovers CAN bus devices. Response: [0x3E, id0, id1, ...]
COMM_BMS_GET_VALUES 0x60 Smart-BMS values (cell-group voltages, balancing, SoC). CAN-forwarded like other cmds. See below.

Problem: GET_VALUES never responded

Symptom: COMM_GET_VALUES (0x04) sent successfully (write-with-response confirmed), but zero notification packets received.

Cause: The ESP32 is a dumb BLE→CAN bridge. It only handles COMM_FW_VERSION locally. All other commands including COMM_GET_VALUES must be addressed to a specific CAN device ID and prefixed with COMM_FORWARD_CAN. Without the prefix the ESP32 has no motor controller CAN ID to forward to.

Fix:

  1. Resolve the motor controller's CAN ID once at setup via Board Probe (COMM_PING_CAN), store it as the Board Transport
  2. Wrap all motor commands with the stored transport: [0x22, canId, <cmd>]
// Setup only: BoardTransportDetector pings to discover responders.
sendPayload(byteArrayOf(COMM_PING_CAN.toByte()))

// Runtime: the stored Board Transport frames each poll — no discovery.
// BoardTransport.Can(canId).frame(cmd) prepends [FORWARD_CAN, canId].
sendPayload(byteArrayOf(
  COMM_FORWARD_CAN.toByte(),
  canId.toByte(),
  COMM_CUSTOM_APP_DATA.toByte(),
  REFLOAT_MAGIC.toByte(),
  REFLOAT_GET_ALLDATA.toByte(),
  2,
))

Connect sequence

CAN id discovery is a setup-time Board Probe (BoardTransportDetector), not part of runtime connect. At runtime the stored Board Transport is read and polling starts directly.

Board Probe (setup, once):
  connect → COMM_FW_VERSION → COMM_PING_CAN → probe each responder + Direct
  → confirm a transport on first valid telemetry sample → store Board Transport

Runtime connect (every session, dumb):
1. nativeConnect(deviceId)                  — GATT connect, MTU 517, CCCD writes
2. seed direct/CAN mode from stored Board Transport
3. poll every 500ms (no discovery probes):
   direct: send [CUSTOM_APP_DATA, 101, GET_ALLDATA, 2]
   CAN:    send [FORWARD_CAN, canId, CUSTOM_APP_DATA, 101, GET_ALLDATA, 2]

BLE write serialization

Android accepts only one GATT characteristic write at a time. The native transport queues every framed packet and sends the next only after the previous write callback. This prevents remote-control repeats and telemetry polling from causing writeCharacteristic busy failures and silently losing commands.

Note: COMM_ALIVE (0x1E) was tried as the first ping — it generates no response, so it cannot confirm the notification path. COMM_FW_VERSION must be used instead.

BMS cell-group values

A smart BMS (e.g. Smart BMS / ANT / JBD over CAN) reports per-cell-group voltages. We read them with COMM_BMS_GET_VALUES (0x60) — the standard VESC BMS command, not anything from the Refloat GET_ALLDATA stream (that only carries pack-level voltage).

Capability detection (at probe and verified at runtime)

Smart-BMS presence and firmware identity are discovered during the Board Probe for each candidate transport. While probing each transport for telemetry, BoardTransportDetector also fires a COMM_BMS_GET_VALUES request and firmware identity requests (COMM_FW_VERSION and Refloat GET_INFO) when available. The facts ride on the chosen BoardCandidate into the saved BoardLink as linkVersion: 4. Native finalization accepts only a candidate from that probe, then persists its complete Last Known Board Config Values before returning the saveable link.

Runtime connect still starts telemetry from the saved Board Transport without rediscovering CAN. After telemetry startup, a background Link Integrity Check lightly re-probes saved facts for the selected transport. If saved facts mismatch or expected BMS stops being observed for a debounce window, the link is treated as mismatched for that Board Session: telemetry can continue, but firmware-dependent commands are blocked until the rider re-links.

BMS is polled only when the saved or freshly verified link says one is present. Unknown legacy links need a re-probe or successful Link Integrity Check before cell data and firmware-dependent capabilities are trusted.

Polling

PollingLoop interleaves a BMS poll into the normal telemetry loop at 1/8 of the telemetry rate (BMS_POLL_STRIDE). Cell voltages change slowly and the reply is large, so a slower cadence avoids crowding the BLE link. The poll reuses the session transport, so it is CAN-forwarded ([0x22, canId, 0x60]) or sent direct exactly like the Refloat poll. The reply arrives unwrapped at the top level as [0x60, ...] (the ESP32 strips the CAN-forward wrapper on responses), with a nested [0x22, ?, 0x60, ...] form also handled defensively.

The loop sends the BMS poll only when link.hasBms === true; otherwise it is skipped entirely — no wasted frames, and BmsCellVoltages shows a definitive "No smart-BMS detected" instead of an open-ended "waiting".

Payload layout (parseBmsValues in VescProtocol.kt)

VESC packs scaled big-endian integers, not IEEE floats: a float32 field is int32 / scale and a float16 field is int16 / scale. Layout mirrors commands.c:

[0]      id = 0x60
float32  v_tot      (÷1e6)   pack voltage
float32  v_charge   (÷1e6)
float32  i_in       (÷1e6)   pack current
float32  i_in_ic    (÷1e6)
float32  ah_cnt     (÷1e3)
float32  wh_cnt     (÷1e3)
u8       cell_num
float16  v_cell[cell_num] (÷1e3)   ← the per-group voltages we surface
u8       bal_state[cell_num]       ← balancing flag per group
u8       temp_adc_num
float16  temps_adc[temp_adc_num] (÷1e2)
float16  temp_ic, temp_hum, hum, temp_max_cell (÷1e2)
u8       soc (×255 → 0–1), soh, can_id, ...

Only the stable prefix (voltages + balancing) is required. soc is best-effort: parsed by walking past the variable-length temp block with bounds checks, so firmware variants with different trailing fields still yield cell data. Sanity guards reject cell_num outside 1–60 and payloads too short for the claimed cell count.

Flow to UI

handleBmsPayload → emit onBmsbleStore.latestBmssummarizeBms (min/max/spread/avg, extreme tagging) → BmsCellVoltages grid on the battery control screen. iOS BMS parsing waits for the CoreBluetooth protocol port and must use real board packets, not synthetic values.