An end-of-line test station for boards, from sequence to yield report.
YAML test sequences with Setup/Main/Cleanup, limits and retries, run against simulated boards through a simulated SCPI DAQ. Per-unit reports, yield, failure Pareto and Cpk.
Scope: Simulated boards and instruments; modelled on NI TestStand concepts, not TestStand itself. Personal portfolio project, not affiliated with any employer.
On a production line the question is not only pass or fail, but why units fail, how often a retest rescues them, and whether a rail is drifting towards its limit. The station answers those after every batch.
A small end-of-line production test sequencer in Python, modelled on the concepts of NI TestStand. It runs a YAML test sequence against simulated boards through a simulated SCPI DAQ/DMM, writes a report per unit and a station log, and summarises a batch with yield, retest rate, a failure Pareto and Cpk.
I built it to learn how a production test station is structured: sequence groups, step types, limits, retries, retest flow and the statistics a test engineer looks at after a shift.
sequences/board_eol.yaml: example sequence with Setup / Main / Cleanup groups, station ID, fixture ID and a serial number pattern.eol/sequence.py: parser and validator (unknown types, calls, keys, missing or inverted limits, duplicate names and YAML errors are rejected with the step named), and limit evaluation.eol/station.py: PyVISA driver for the DAQ, the step calls, and the per-unit execution: retries per step with attempt count, stop-on-fail or continue per step, Cleanup always runs, an exception in a step becomes an Error result instead of stopping the station, simulated operator prompts and simulated barcode scan checked againstserial_pattern.eol/dut.py: simulated board with three rails (5V0, 3V3, 1V8), idle current, three components and a firmware version. Unit-to-unit spread is about 0.5 % on the rails. Defect injection: rail out of tolerance, missing component, intermittent fixture contact (reads 0 V at random, usually fixed by a re-seat), wrong firmware, high current.eol/daqsim.py: SCPI DAQ simulator vendored unchanged from my daq-testbench. The DUT "drives" a DAQ input viaSOUR:VOLT, the station reads it back withMEAS:VOLT?, so measurements carry the simulator's offset, gain error and noise. Current is read as a voltage across a 0.1 ohm shunt on the 0.1 V range.eol/__main__.py: batch runner. A failed unit is re-seated and retested once.- Outputs in
out/:units/<serial>_run<n>.jsonand.md,station_log.csv(one row per step per run),batch_summary.mdand.json.
pip install -r requirements.txt
pytest -q
python -m eol sequences/board_eol.yaml --units 200 --seed 7 --out out
python -m eol sequences/board_eol.yaml --units 50 --rates '{"missing_component": 0.2}'
| TestStand | Here |
|---|---|
| Sequence file, Setup / Main / Cleanup step groups | YAML file with setup, main, cleanup lists |
| Numeric Limit Test, Pass/Fail Test, String Value Test, Action | numeric, passfail, string, action step types |
| Comparison types (GELE, GTLT, GE, LT, EQ, ...) | same names in comp, with low, high, units |
| Step loop / retry on fail | retries: N, attempts recorded per step |
| Step failure causes sequence failure / skip | on_fail: stop (default) skips the remaining Main steps; continue keeps going |
| Code modules / adapters | Python functions in CALLS |
| Process model (serial number entry, UUT loop, report, database logging) | run_batch: serial scan, per-unit run, retest, report files, CSV station log |
| Station globals | station and fixture ID in the sequence file |
| Operator interface | not built; prompts are auto-acknowledged and logged |
| Metric | Value |
|---|---|
| Units | 200 |
| First-pass yield | 88.5% |
| Final yield (after retest) | 91.0% |
| Retest rate | 11.5% |
| Step retries used (run 1) | 36 |
Failure Pareto (first run, first failing step): Rail 5V0 5, Idle current 4, Connector present 3, Firmware version 3, Rail 1V8 3, Rail 3V3 3, ETH PHY present 1, PMIC present 1.
| Step | n | Mean | Std | Low | High | Units | Cpk |
|---|---|---|---|---|---|---|---|
| Rail 5V0 | 195 | 4.999 | 0.0253 | 4.85 | 5.15 | V | 1.965 |
| Rail 3V3 | 192 | 3.299 | 0.0174 | 3.2 | 3.4 | V | 1.9 |
| Rail 1V8 | 189 | 1.801 | 0.00927 | 1.746 | 1.854 | V | 1.899 |
| Idle current | 185 | 180.6 | 5.7 | 140 | 230 | mA | 2.372 |
Definitions: first-pass yield = units passing on run 1 / units. Final yield = units whose last run passed / units. Retest rate = units run more than once / units. Cpk = min(USL - mean, mean - LSL) / (3 * s), sample standard deviation, one-sided when only one limit exists. Cpk here uses passing measurements only, because 0 V contact faults and defective units would otherwise dominate the spread; that makes it optimistic. The retry count shows intermittent contacts being absorbed by step retries, which is also how retries can hide a fixture problem on a real line.
52 pytest tests: every comparison type at and around its limits, non-numeric and NaN values, string and pass/fail strictness, 13 sequence parsing error cases, retry recovery and exhaustion, stop-on-fail vs continue with Cleanup still running, step exceptions, operator prompts and serial validation, yield / Pareto / Cpk on hand computed data, and end-to-end batches (all good units give 100 % yield; five injected defects give exactly 35/40 first pass and 36/40 final). CI runs them on Python 3.11 and 3.12 and uploads a sample batch as an artifact.
- Simulated DUT and simulated instruments only. Nothing has run against real hardware or on a production line.
- This is not NI TestStand and does not read TestStand sequence files. It borrows the concepts to show I understand them.
- Limits and defect rates are illustrative, not from any real product.
- No operator UI, no database, no MES integration, no parallel or batch fixtures, no measurement uncertainty or guard banding, no Gage R&R.
- Not affiliated with Axis Communications or National Instruments.