Skip to content

Preserve FastLanes measurement tracebacks in fallback results #197

Closed

Description

@Anionix

The FastLanes workflow writes Python runtime failures to measure.log, but the fallback result only reads measure-error.txt. A measurement failure can therefore be reported with error=none even though a traceback exists.

Acceptance:

  • include the measurement log path or a bounded traceback excerpt in the fallback JSON;
  • distinguish validation, runtime, and unavailable failures;
  • add a workflow test for a runner exception.

Origin: post-merge review of PR #169.

Activity

  1. Anionix commented on Jul 16, 2026

    @Anionix
    OwnerAuthor

    This review finding is already fixed on current main: the fallback now reads a bounded tail from measure.log when measure-error.txt is absent. Closing the audit issue as completed; the original PR thread is resolved/outdated.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment