Skip to content

Releases: LucaSchenetti/Fieldbus-Studio

Fieldbus Studio 1.1.0

Choose a tag to compare

@LucaSchenetti LucaSchenetti released this 18 Jul 23:09

🇬🇧 English

New Type column in the Modbus and S7 server datastore tables.

When you set a typed value (float32, int32, ASCII, REAL, STRING, …) the table
now shows the decoded, human-readable value (e.g. float32 = 3.14) next to the
raw registers/bytes that compose it. The first row of the group shows the
value, the following rows are marked with ↳ type. The value follows the
current datastore contents, so it updates when a client overwrites the
registers. Right-click a row to remove an interpretation; interpretations are
kept across restarts and saved with the Modbus datastore JSON file.

Also improved: table data is now center-aligned in all columns.

Download: grab Fieldbus_Studio.exe below and double-click to run.
Requirements: Windows. No installation needed.

On the first launch Windows SmartScreen may warn about an unrecognised
publisher (the app is not code-signed): click "More info → Run anyway".

🇮🇹 Italiano

Nuova colonna Tipo nelle tabelle datastore dei server Modbus e S7.

Quando imposti un valore tipizzato (float32, int32, ASCII, REAL, STRING, …) la
tabella ora mostra il valore decodificato e leggibile (es. float32 = 3.14)
accanto ai registri/byte grezzi che lo compongono. La prima riga del gruppo
mostra il valore, le successive sono marcate con ↳ tipo. Il valore segue il
contenuto corrente del datastore, quindi si aggiorna se un client sovrascrive i
registri. Tasto destro su una riga per rimuovere un'interpretazione; le
interpretazioni restano dopo il riavvio e vengono salvate col file JSON del
datastore Modbus.

Migliorato inoltre: i dati delle tabelle sono ora centrati in tutte le colonne.

Download: scarica Fieldbus_Studio.exe qui sotto e fai doppio clic per avviarlo.
Requisiti: Windows. Nessuna installazione necessaria.

Al primo avvio Windows SmartScreen potrebbe segnalare un editore non
riconosciuto (l'app non è firmata): clicca "Ulteriori informazioni → Esegui comunque".

Fieldbus Studio 1.0.0

Choose a tag to compare

@LucaSchenetti LucaSchenetti released this 09 Jul 21:30
0a4f343

🇬🇧 English

First public release of Fieldbus Studio.

Multi-protocol desktop client and server (Modbus, PROFINET S7, EtherNet/IP, CANopen) with a modern PySide6/Qt GUI.

Download: grab Fieldbus_Studio.exe below and double-click to run.
Requirements: Windows. No installation needed.

On the first launch Windows SmartScreen may warn about an unrecognised publisher (the app is not code-signed): click "More info → Run anyway".


🇮🇹 Italiano

Prima versione pubblica di Fieldbus Studio.

Client e server desktop multi-protocollo (Modbus, PROFINET S7, EtherNet/IP, CANopen) con interfaccia moderna PySide6/Qt.

Download: scarica Fieldbus_Studio.exe qui sotto e fai doppio clic per avviarlo.
Requisiti: Windows. Nessuna installazione necessaria.

Al primo avvio Windows SmartScreen potrebbe segnalare un editore non riconosciuto (l'app non è firmata): clicca "Ulteriori informazioni → Esegui comunque".