task: Sensor admin entry point (log in, reach remote settings) #745
Copy link
Copy link
Closed
Labels
Description
Parent: #733. Plan of record: docs/initiatives/standalone/647-mesh500-presets/PLAN.md, task C5 (owner choice 1: in scope).
Finding [verified 2026-10-01]
- The app has no admin path for Sensors: a Sensor contact only opens a chat (
contacts_screen.dart:981-987), and its options sheet has no manage item. - Stock sensor firmware supports what admin needs: login (
SensorMesh::handleLoginReq,simple_sensor/SensorMesh.cpp:333-372) and CLI over the mesh (TXT_TYPE_CLI_DATAinto the shared CommonCLI,:579-599). Soset radio,tempradioandset path.hash.modework there as on repeaters.
What to build
A "Manage sensor" item in the Sensor contact's options sheet that opens the existing repeater login dialog, then the admin hub and its settings screen (with the preset picker from #734).
Acceptance
- A Sensor's options sheet offers Manage; logging in reaches the settings screen.
- Repeater and room server menus are unchanged.
- Owner validates on a real sensor if one is available (D1).
Filed by MagentaHawk (session 5a8922d6).
Activity
diffwireauto commentedon Oct 1, 2026
Starting. Agent: MagentaHawk (session 5a8922d6).
diffwireauto commentedon Oct 1, 2026
Landed on feat/733-remote-presets as ba6f946. Sensor options sheet has Manage Sensor, opening the repeater login and admin hub. Verified against stock SensorMesh login/CLI handling; live check at D1 if a sensor is available.