Skip to content

task: Sensor admin entry point (log in, reach remote settings) #745

Closed

Description

@diffwireauto

Parent: #733. Plan of record: docs/initiatives/standalone/647-mesh500-presets/PLAN.md, task C5 (owner choice 1: in scope).

Finding [verified 2026-10-01]

  • The app has no admin path for Sensors: a Sensor contact only opens a chat (contacts_screen.dart:981-987), and its options sheet has no manage item.
  • Stock sensor firmware supports what admin needs: login (SensorMesh::handleLoginReq, simple_sensor/SensorMesh.cpp:333-372) and CLI over the mesh (TXT_TYPE_CLI_DATA into the shared CommonCLI, :579-599). So set radio, tempradio and set path.hash.mode work there as on repeaters.

What to build

A "Manage sensor" item in the Sensor contact's options sheet that opens the existing repeater login dialog, then the admin hub and its settings screen (with the preset picker from #734).

Acceptance

  • A Sensor's options sheet offers Manage; logging in reaches the settings screen.
  • Repeater and room server menus are unchanged.
  • Owner validates on a real sensor if one is available (D1).

Filed by MagentaHawk (session 5a8922d6).

Activity

  1. diffwireauto commented on Oct 1, 2026

    @diffwireauto
    MemberAuthor

    Starting. Agent: MagentaHawk (session 5a8922d6).

  2. diffwireauto commented on Oct 1, 2026

    @diffwireauto
    MemberAuthor

    Landed on feat/733-remote-presets as ba6f946. Sensor options sheet has Manage Sensor, opening the repeater login and admin hub. Verified against stock SensorMesh login/CLI handling; live check at D1 if a sensor is available.