Skip to content

feat: dedicated hemolysis risk scorer (detection AUROC=0.9218) - #114

Merged
cschanhniem merged 1 commit into
mainfrom
oamp-loop-2026-07-01
Jun 30, 2026
Merged

cschanhniem merged 1 commit into
mainfrom
oamp-loop-2026-07-01

Conversation

@cschanhniem

Copy link
Copy Markdown
Collaborator

Summary

Addresses the safety scorer's confirmed hemolysis blind spot (detection AUROC=0.3844, documented in v0.5.9) with a standalone 4-component risk score.

Changes

New module: scoring/hemolysis.py

A dedicated hemolysis risk scorer combining four empirically-validated components from the selectivity benchmark:

Component Individual AUROC Weight
Synthesis difficulty 0.8027 0.30
Aromatic fraction 0.8299 0.30
Cationic-on-hydrophobic-face 0.7585 0.20
Cysteine fraction 0.7500 0.20

Combined detection AUROC=0.9218 (CI: 0.82-0.99) -- first statistically significant hemolysis detector.

Integration

  • Selectivity benchmark: hemolysis_risk added as risk-direction score
  • Expert composite: hemolysis_safety component (weight 0.10)
  • Safety scorer UNCHANGED -- standard AUROC remains 0.7832

Key metrics

Metric Before After
Hemolysis detection AUROC 0.3844 (safety) 0.9218 (hemolysis_risk)
Expert composite detection 0.5119 0.6429
Standard AUROC 0.7832 0.7832 (unchanged)
Total tests 1453 1471

Test plan

  • 15 new tests in test_hemolysis_risk.py
  • 3 new tests in test_selectivity_benchmark.py
  • Updated test_expert_ablation.py
  • All 1471 tests pass (7 skipped)

…82-0.99)

Addresses the safety scorer's confirmed hemolysis blind spot (detection
AUROC=0.3844, documented in v0.5.9) with a standalone 4-component risk
score derived from empirically-validated signals:

- Synthesis difficulty (1 - synthesis_feasibility) — AUROC=0.8027
- Aromatic fraction (F/W/Y density) — AUROC=0.8299
- Cationic-on-hydrophobic-face fraction — AUROC=0.7585
- Cysteine fraction (beta-sheet defensin class) — AUROC=0.7500

Combined detection AUROC=0.9218 (CI: 0.82-0.99) — first statistically
significant hemolysis detector in the pipeline.

Key design decisions:
- Safety scorer UNCHANGED — standard AUROC remains 0.7832
- Hemolysis risk is complementary, not replacement
- Integrated into expert composite as hemolysis_safety (weight 0.10)
- Expert composite hemolysis detection: 0.5119 → 0.6429
- hemolysis_safety is anti-signal on AMP-vs-decoy (AUROC=0.3285) —
  expected, confirms it measures within-AMP property

15 new tests in test_hemolysis_risk.py; 3 new selectivity tests;
1471 total tests (7 skipped).
@cschanhniem
cschanhniem merged commit f863407 into main Jun 30, 2026
1 check passed
cschanhniem added a commit that referenced this pull request Jun 30, 2026
…SP, correct small-sample inflation (#115)

* feat(bench): expand hemolysis reference 42 to 238 peptides using DBAASP, correct small-sample inflation in hemolysis risk scorer

The within-AMP selectivity benchmark (PR #113/#114) ran on only 42 peptides
(14 hemolytic vs 21 selective, n=35 binary). The dedicated hemolysis risk
scorer detection AUROC=0.9218 (CI 0.82-0.99) was based on this tiny set.

DBAASP v3 hemolytic activity data (already in data/novelty_db/) contains
887 unique peptides with human erythrocyte 50 percent hemolysis measurements.
This PR extracts 196 new peptides with HC50 values, converts uM to ug/ml
using peptide molecular weight, and merges with the existing reference.

Expanded benchmark (n=179 binary: 54 hemolytic vs 125 selective):
  hemolysis_risk detection AUROC: 0.9218 to 0.5650 (CI 0.47-0.66) NOT significant
  safety detection AUROC: 0.3844 to 0.5116 (CI 0.43-0.60) still not significant
  selectivity_proxy detection AUROC: 0.5744 (CI 0.50-0.66) borderline
  serum_stability: 0.5873 (CI 0.51-0.66) significant risk detector

The original 0.92 AUROC was small-sample inflation. This is exactly the
kind of self-deception the project adversarial benchmark philosophy is
designed to catch. No scorer should be described as a statistically
significant hemolysis detector based on the expanded set.

Changes:
- scripts/expand_hemolysis_benchmark.py: extraction and unit conversion
- examples/validation/hemolysis_reference.csv: 42 to 238 peptides
- tests: test renamed from significant detector to direction correct
- docs: METRICS_CURRENT.md, ROADMAP.md, BENCHMARK_CARD.md updated
- src: hemolysis.py and expert.py docstrings corrected

All 1471 tests pass. No regressions.

Constraint: DBAASP hemolysis data already in repo (data/novelty_db/); no new downloads needed
Rejected: Using raw uM thresholds | Existing benchmark uses ug/ml; converting preserves comparability
Rejected: Filtering to only uM data | Would lose 107 peptides with only ug/ml measurements
Directive: Do not describe hemolysis_risk as statistically significant without re-validating on expanded set
Confidence: high
Scope-risk: narrow
Tested: 1471 tests pass, 7 skipped; benchmark run on expanded set; all doc references updated

Co-authored-by: OmX <noreply@omx.ai>

* fix: Python 3.11 f-string compatibility in test_selectivity_benchmark

---------

Co-authored-by: OmX <noreply@omx.ai>
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment