Repository navigation
Conversation
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
Brings the ADR-0013 acceptance and the maintainer's default answers into the stack. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
Plan view with on-demand ECharts, next planned actions, battery card with mode switch, forecast accuracy panel; demo battery control flag, energy prefs solar forecast entries, workday and weather site roles. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
Snapshot so nothing is lost when the usage limit stops the session; not yet checked. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
…eps, STATUS and plan notes (WP11) Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
… step (WP11) Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
…(WP11) Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
…t and status (WP13) Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
…WP13) Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
…every window, reset fallback, label entries (WP11 review) - tariff: the formula is only dropped when the source is certainly an end price - plan store: now = browser clock + server offset on a minute tick, refetch after reconnect, Now view says when the plan is stale or not followed - HT/NT periods and fee windows need a price; a changed adapter, link or timer resets fallback_measured in the form - chart and table show the planned devices; Forecast.Solar entries show labels from the device registry and a saved id stays visible; times use the Home Assistant time zone - BatteryCard: only real capabilities, no unreachable cap_generic key Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
…00 kB Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
…romium for ubuntu 26.04) Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VHXsfH6PkT62o9idByAd6e
Owner
Author
|
Der Check Frontend ist rot, aber nicht wegen dieses PRs. Build, Vitest und Bundle-Budgets waren grün (119,9 kB First Paint). Fehlgeschlagen ist erst
GitHub hat Behoben, indem der Frontend-Job auf
Damit wird das Problem schon mit dem ersten Merge behoben. Ein Playwright-Update kann später als eigener PR folgen. Generated by Claude Code |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Gestapelt auf #33 (PR 4-G). Enthält außerdem den Merge des 4-A-Branches mit der Annahme von ADR-0013. Das ist der letzte PR von Phase 4; die Basis wird nach dem Merge der Vorgänger umgestellt.
Was
WP11 – Oberfläche
#/plan:Battery:MinSocund zum Modbus-Hubrole_entities,action_params,series_key,price_includesundconfig_entry_idverworfen. Eine gespeicherte Preisformel geht beim schnellen Speichern nicht mehr verloren. Beides ist mit Round-trip-Tests abgesichert.solar_forecast_entriesundsolar_forecast_labelsin/wizard/energy-prefsworkdayundweatherSUNCORE_DEMO_BATTERY_CONTROL(standardmäßig aus, nur im Demo-Pfad)WP13 – Doku, Übersetzungen, STATUS
docs/user/{en,de}/planning-and-battery.md. Er erklärt Planer, Prognosen, Tarife, Risikostufe, Puffer/Ziel, Strategien, Netzladen, Akku-Modi und Freigabe. Dazu:Battery:MinSocDOCS.md, README, Architektur, Roadmap, STATUS (inklusive Merge-Reihenfolge).Warum
Exit-Kriterium von Phase 4: „Fahrplan mit Akku-Strategie und ‚Warum?‘ auf dem System des Maintainers“. Ohne Oberfläche und Doku ist das nicht nutzbar.
Wie getestet
Checks:
./scripts/check.shgrün: 4655 Python-Tests, Abdeckung 96 %, 275 Vitest-Tests. markdownlint ohne Fehler.Playwright gegen die Demo: 237 bestanden, 0 fehlgeschlagen (144 Screenshot-Specs übersprungen), auf Desktop, Phone und Tablet. Geprüft werden:
Bundle (gzip):
#/plan)Screenshots: alle aus dem Demo-Modus, jede PNG unter 300 kB.
Screenshots (Demo-Modus)
Alle 24 Varianten (hell/dunkel, Phone/Tablet, en/de) liegen in
docs/assets/screenshots/.Risiken
UNVERIFIED): HA-Menünamen für deaktivierte Entitäten und der Modbus-Hub. Die Anleitung ist nicht an einem echten HA durchgeklickt.Safety-Review
control-safety: Messverfahren für den Rückfall-Timer freigegeben mit Änderungen (R1–R7, eingearbeitet in 67439b4).
Die Anleitung misst den Hardware-Rückfall (§3.5, Register 1288) grundsätzlich richtig: Watchdog aus, App bleibt gestoppt, die Wiederherstellungszeile im Log liegt nach dem Rückfall. Der Code stimmt damit überein: Timer 60 s, Heartbeat 20 s, Rückfallregister = max(Modell, eigene Grenzen), vor dem ersten Limit gelesen; Begrenzung auf „assistiert“ bis
fallback_measured.Eingearbeitet:
docker killohne--signal, nie Stoppen oder Neustarten. Bei SIGTERM gibt SunCore den Akku frei, das täuscht einen Rückfall vor.fallback_measuredbleibt bei jedem Fehlschlagfalse.fallback_measuredist eine ungeprüfte Aussage des Nutzers und gilt nur für den gemessenen Timer, diesen Wechselrichter und diese Firmware.Die deutsche Fassung ist gleichwertig. Code-Schreibpfade ändert dieser PR nicht; die Invarianten aus BRIEF §5 sind unberührt.
Folgeaufgabe (Code, eigener PR, S1):
fallback_measuredan den gemessenenfallback_timeout_sbinden. Heute bleibt die Begrenzung auch nach einer späteren Timer-Erhöhung aufgehoben. Das braucht einen ADR-0013-Nachtrag und einen Gate-Test. Das Formular setzt den Wert bei einer Timer-Änderung schon jetzt zurück.Checkliste
enunddeDOCS.md, README, Roadmap); Screenshots aus dem Demo-Modusdocs/STATUS.mdaktualisiertUNVERIFIEDOffene Fragen an den Maintainer
Ohne Antwort gilt jeweils der Standard.
Folgeaufgabe: Ein Schalter in der Oberfläche für „Rückfall gemessen“ (heute: Export → Datei bearbeiten → Import) und die Bindung an den Timer (S1). Standard: eigener PR nach Phase 4.
Nicht in der Oberfläche:
action_params/series_key(z. B. Nord Pool) und der Lern-EinstellungenStandard: Phase 5 (Expertenmodus).
Kalibrierladung: nur ein Konfigurationsfeld, der Planer nutzt sie noch nicht (Roadmap ⬜). Standard: später.
Nächste Schritte für dich (STATUS):
Battery:MinSocaktivieren → Akku auf „assistiert“.Generated by Claude Code