Skip to content
Raiyan832Public

About

EMG-controlled gripper prototype using ESP32, MyoWare 2, FSR contact sensing, and high-torque servo control.

Topics

Resources

Stars

0 stars

Watchers

0 watching

Forks

Repository files navigation

MyoGrip

MyoGrip is an experimental EMG-controlled gripper prototype built around an ESP32, a MyoWare 2 muscle sensor, an FSR contact sensor, and a high-torque PWM servo.

This repository serves as an engineering portfolio, development workspace, and historical archive of the project.

Repository status

The repository was reconstructed from original source packages, Git snapshots, raw test data, historical documents, and recovered development artifacts in October 2026.

Historical recovery is preserved separately from future maintained development.

firmware/current/ is intentionally not designated as a final firmware implementation yet.

Core hardware

  • ESP32 DevKit / ESP-32S
  • MyoWare 2 muscle sensor using ENV output
  • GPIO34: MyoWare ENV
  • GPIO35: FSR voltage-divider output
  • GPIO18: servo PWM
  • Hiwonder HPS-3518SG PWM servo
  • 7.2 V NiMH actuator battery
  • 5 A actuator fuse
  • maintained actuator-power switch
  • 10 kOhm FSR divider resistor
  • common ESP32/servo signal ground

The servo power path is separate from the ESP32 and breadboard power domain.

Recovered development history

The historical archive includes:

  • original PlatformIO ESP32 bring-up firmware
  • Gate 0 hardware and delivery review
  • Gate 1 ESP32 logic-only qualification
  • formal manual-only safety scaffold
  • servo keyboard and manual-control experiments
  • servo ROM and full-speed qualification firmware
  • corrected servo test runner
  • FSR characterization
  • MyoWare visualization and placement work
  • September 11 integrated ESP32, MyoWare, FSR, and servo firmware
  • September 11 automatically calibrated EMG grip/release controller
  • raw September 11 serial telemetry

The September 11 automatic EMG controller was reported working during bench development. A final validated FSR force-stop implementation has not been established from the recovered record.

Repository layout

archive/
    gate-snapshots/          Sanitized Gate 0 and Gate 1 snapshots
    historical-documents/    Historical project documents
    original-artifacts/      Byte-preserved project ZIP archives
    provenance/              Hashes and migration records

data/
    characterization/        Historical FSR characterization
    raw/                     Raw experimental logs

docs/
    architecture/            Current architectural interpretation
    history/                 Project history and recovery documentation
    testing/                 Current testing documentation

firmware/
    historical/              Recovered historical firmware
    current/                 Future maintained firmware

hardware/
    electrical/              Project electrical artifacts
    mechanical/              Mechanical evidence
    vendor-reference/        Reference index only

software/
    historical/              Recovered historical host utilities

Historical fidelity

Historical files are evidence. Do not silently fix, modernize, merge, or normalize recovered revisions.

The project used multiple architectures over time, including an early HPS-2527MG concept, an obsolete LiPo/UBEC planning branch, and later direct-NiMH HPS-3518SG development.

Those stages remain separate.

Safety

MyoGrip is a prototype and is not a finished medical device.

Development rules include:

  • keep actuator power separate from the ESP32/breadboard supply
  • never route servo stall current through a breadboard
  • maintain a common signal-ground reference
  • establish mechanical travel limits experimentally
  • validate FSR behavior before using it as a force limiter
  • do not treat the FSR as a precision load cell without calibration
  • do not claim a test passed unless it was actually performed and reported
  • use battery-isolated equipment for on-body MyoWare work

Third-party material

Manufacturer manuals and vendor CAD used during development are not redistributed in this public repository.

Reference filenames and hashes are retained where historically relevant.

Historical recovery

See:

  • docs/history/HISTORICAL_RECOVERY.md
  • docs/architecture/CURRENT_BASELINE.md
  • archive/provenance/

License

See LICENSE.

About

EMG-controlled gripper prototype using ESP32, MyoWare 2, FSR contact sensing, and high-torque servo control.

Topics

Resources

Stars

0 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages