Comparison of power consumption and battery lifetime for IoB nodes operating with WiR and Bluetooth protocols.
EQS-HBC and Wi-R
[1] B. Chatterjee, P. Mohseni, and S. Sen, “Bioelectronic sensor nodes for the internet of bodies,” Annual Review of Biomedical Engineering, vol. 25, no. 1, p. null, 2023, pMID: 36913705. [Online]. Available: https://doi.org/10.1146/annurev-bioeng-110220-112448
[2] S. Maity, M. He, M. Nath, D. Das, B. Chatterjee, and S. Sen, “Bio-physical modeling, characterization, and optimization of electro- quasistatic human body communication,” IEEE Transactions on Biomed- ical Engineering, vol. 66, no. 6, pp. 1791–1802, 2018
[3] S. Maity et al., “On the safety of human body communication,” IEEE Transactions on Biomedical Engineering, pp. 1–1, 2020.
[4] S. Sen, “Wi-r technology white paper,” Ixana, 2023.
References for Sensing Energy Efficiency Survey
[1] J. P. Uehlin, W. A. Smith, V. R. Pamula, S. I. Perlmutter, J. C. Rudell, and V. S. Sathe, “A 0.0023 mm2/ch. delta-encoded, time-division multiplexed mixed-signal ecog recording architecture with stimulus artifact suppression,” IEEE Transactions on Biomedical Circuits and Systems, vol. 14, no. 2, pp. 319–331, 2020.
[2] R. Muller, H.-P. Le, W. Li, P. Ledochowitsch, S. Gambini, T. Bjorninen, A. Koralek, J. M. Carmena, M. M. Maharbiz, E. Alon, and J. M. Rabaey, “A minimally invasive 64-channel wireless ecog implant,” IEEE Journal of Solid-State Circuits, vol. 50, no. 1, pp. 344–359, 2015.
[3] A. E. Mendrela, J. Cho, J. A. Fredenburg, C. A. Chestek, M. P. Flynn, and E. Yoon, “Enabling closed-loop neural interface: A bi-directional interface circuit with stimulation artifact cancellation and cross-channel cm noise suppression,” in 2015 Symposium on VLSI Circuits (VLSI Circuits), 2015, pp. C108–C109.
[4] W.-M. Chen, H. Chiueh, T.-J. Chen, C.-L. Ho, C. Jeng, M.-D. Ker, C.-Y. Lin, Y.-C. Huang, C.-W. Chou, T.-Y. Fan, M.-S. Cheng, Y.-L. Hsin, S.- F. Liang, Y.-L. Wang, F.-Z. Shaw, Y.-H. Huang, C.-H. Yang, and C.-Y. Wu, “A fully integrated 8-channel closed-loop neural-prosthetic cmos soc for real-time epileptic seizure control,” IEEE Journal of Solid-State Circuits, vol. 49, no. 1, pp. 232–247, 2014.
[5] B. C. Raducanu, R. F. Yazicioglu, C. M. Lopez, M. Ballini, J. Putzeys, S. Wang, A. Andrei, M. Welkenhuysen, N. van Helleputte, S. Musa, R. Puers, F. Kloosterman, C. van Hoof, and S. Mitra, “Time multiplexed active neural probe with 678 parallel recording sites,” in 2016 46th European Solid-State Device Research Conference (ESSDERC), 2016, pp. 385–388.
[6] J. Warchall, P. Theilmann, Y. Ouyang, H. Garudadri, and P. P. Mercier, “22.2 a rugged wearable modular exg platform employing a distributed scalable multi-channel fm-adc achieving 101db input dynamic range and motion-artifact resilience,” in 2019 IEEE International Solid- State Circuits Conference - (ISSCC), 2019, pp. 362–364.
[7] J. Xu, B. Busze, H. Kim, K. Makinwa, C. Van Hoof, and R. F. Yazicioglu, “24.7 a 60nv/hz 15-channel digital active electrode system for portable biopotential signal acquisition,” in 2014 IEEE International Solid-State Circuits Conference Digest of Technical Papers (ISSCC), 2014, pp. 424–425.
[8] N. Van Helleputte, M. Konijnenburg, J. Pettine, D.-W. Jee, H. Kim, A. Morgado, R. Van Wegberg, T. Torfs, R. Mohan, A. Breeschoten et al., “A 345 μw multi-sensor biomedical soc with bio-impedance, 3-channel ecg, motion artifact reduction, and integrated dsp,” IEEE Journal of Solid-State Circuits, vol. 50, no. 1, pp. 230–244, 2014.
[9] R. Rieger and M. Rif’an, “Integrated exg, vibration and temperature measurement front-end for wearable sensing,” IEEE Transactions on Circuits and Systems I: Regular Papers, vol. 65, no. 8, pp. 2422–2430, 2018.
[10] G. O’Leary, M. R. Pazhouhandeh, M. Chang, D. Groppe, T. A. Valiante, N. Verma, and R. Genov, “A recursive-memory brain-state classifier with 32-channel track-and-zoom δ 2 σ adcs and charge-balanced programmable waveform neurostimulators,” in 2018 IEEE International Solid-State Circuits Conference-(ISSCC). IEEE, 2018, pp. 296–298.
[11] P. Sch¨onle, F. Glaser, T. Burger, G. Rovere, L. Benini, and Q. Huang, “A multi-sensor and parallel processing soc for miniaturized medical instrumentation,” IEEE Journal of Solid-State Circuits, vol. 53, no. 7, pp. 2076–2087, 2018.
[12] Q. Lin, S. Song, R. V. Wegberg, M. Konijnenburg, D. Biswas, C. V. Hoof, F. Tavernier, and N. V. Helleputte, “28.3 a 28w 134db dr 2nd-order noise-shaping slope light-to-digital converter for chest ppg monitoring,” in 2021 IEEE International Solid- State Circuits Conference (ISSCC), vol. 64, 2021, pp. 390–392.
[13] A. Caizzone, A. Boukhayma, and C. Enz, “17.8 a 2.6w monolithic cmos photoplethysmographic sensor operating with 2w led power,” in 2019 IEEE International Solid- State Circuits Conference - (ISSCC), 2019, pp. 290–291.
[14] H. Ha, W. Sijbers, R. Van Wegberg, J. Xu, M. Konijnenburg, P. Vis, A. Breeschoten, S. Song, C. Van Hoof, and N. V. Helleputte, “A bioimpedance readout ic with digital-assisted baseline cancellation for twoelectrode measurement,” IEEE Journal of Solid-State Circuits, vol. 54, no. 11, pp. 2969–2979, 2019.
[15] Analog Devices. MAX30001, Ultra-Low-Power, Single-Channel Integrated Biopotential (ECG, R-to-R, and Pace Detection) and Bioimpedance (BioZ) AFE. [Online]. Available: https://www.analog.com/en/products/max30001.html