Kennfeld web13 - #30
Merged
Merged
Conversation
Subject: [PATCH] Power map for the Evoblock WEB 13/20 Read from the max. curves of the diagram "Heizleistung WEB 13/20-A-RMD-A" in the Weishaupt Fachinformation 83603813, p. 19, for W35, W45, W55, W65 and W75 between -20 and +20 degC. Five flow curves instead of the usual two: the Evoblock runs up to 75 degC flow, and the curves differ most there. -25 degC and 40 degC carry the nearest value on flat (operating range -25 ... 40 degC); W75 stays at 12.5 kW below -7 degC, where its curve ends. Compiled without scipy: the natural spline overshoots the max. curve by up to ~650 W around +15 degC because of the steep step between 7 and 12 degC. Check points from the data sheet: A-7/W35 13.15 kW and A2/W35 13.04 kW; the grid gives 13.15 and 13.00 kW. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Author
|
Thank you so much! |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Power map for the Evoblock WEB 13/20
Adds
weishaupt_web13_kennfeld.jsonwith its preview picture and names theWEB series in the README. No code changes.
Source: Weishaupt Fachinformation 83603813, p. 19, diagram
"Heizleistung WEB 13/20-A-RMD-A" – the max. curves for W35, W45, W55, W65
and W75, read off the graph between -20 and +20 °C.
Five flow curves instead of the usual two: the Evoblock runs up to 75 °C
flow.
kennfeld.pyinterpolates over any number ofknown_t, and the gridpasses
_looks_like_a_grid(); the picture passesis_static_picture().Outside the graph:
sheet: -25 … 40 °C).
Compiled without scipy (
compile_kennfeld.py, numpy + pygal 3.1.3): thenatural spline overshoots the max. curve by up to ~650 W around +15 °C
because of the steep step between 7 and 12 °C; straight lines follow the
graph.
Check points (data sheet): A-7/W35 13.15 kW, A2/W35 13.04 kW → grid
13.15 / 13.00 kW.
Tests:
tests/test_kennfeld.pyandtests/test_config_flow.pypass(HA 2026.10.4, Python 3.14). The full suite shows the same 24 failures with
and without this change, all in
test_scan_tool.py/test_capture_starter.py(Windows starter tests), unrelated.
Heat pump this is for: WEB 13/20 (WEB CPU V5.7).
🤖 Generated with Claude Code