111 changes: 111 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -9,8 +9,119 @@ Version numbers follow [Semantic Versioning](https://semver.org/).

## [0.11.0] - 2026-06-29

### Added

- **EtherNet/IP (ENIP) + CIP protocol analyzer** — the headline feature of this release
(Feature #316, STORY-130..139, PRs #317–#334, ADR-010). wirerust now analyzes TCP/44818
flows using the ODVA EtherNet/IP + Common Industrial Protocol (CIP) stack. The analyzer
is enabled with `--enip` (also covered by `--all`) and requires stream reassembly.

**Protocol coverage:**

- Parses the 24-byte ENIP encapsulation header (all fields, little-endian per ODVA
specification): command, length, session_handle, status, sender_context, options.
[STORY-130, PR #317, BC-2.17.001/002]
- Classifies all 65,536 possible u16 command values into the 9 ODVA known commands
(ListServices, ListIdentity, ListInterfaces, RegisterSession, UnRegisterSession,
SendRRData, SendUnitData, IndicateStatus, Cancel) plus an `Unknown` catch-all.
[STORY-130, PR #317, BC-2.17.004]
- Parses Common Packet Format (CPF) item lists from `SendRRData` (0x006F) and
`SendUnitData` (0x0070) payloads: bounded item-count walk, type_id recognition for
Null Address (0x0000), Connected Address (0x00A1), Connected Data (0x00B1), and
Unconnected Data (0x00B2) items. CIP service extraction and request-path segment
parse apply to Unconnected Data Items (0x00B2) only in this release.
[STORY-132, PR #319, BC-2.17.005/006/007/009]
- Dispatched as Rule 7 in the `StreamDispatcher` — port-44818 fallback after the
existing TLS, HTTP, Modbus (port 502), and DNP3 (port 20000) rules. Content-signature
rules (TLS record, HTTP prefix) take priority. [STORY-131, PR #318, ADR-010 Decision 1]
- Per-flow state (`EnipFlowState`) with a 600-byte per-direction carry buffer
(`carry_c2s` / `carry_s2c`), frame-walk loop, and session summary folded at
capture end. [STORY-136/137/138, PRs #326–#329, BC-2.17.016/017/021]

**CLI flags:**

- `--enip` — enable EtherNet/IP TCP analysis (default-off; included by `--all`)
- `--enip-write-burst-threshold N` — T0836 write-burst threshold: fires when more than
N CIP write-class service requests (SetAttributesAll, SetAttributeList,
SetAttributeSingle) are observed in any 1-second window per flow (default: 50)
- `--enip-error-burst-threshold M` — T0888 error-burst threshold: fires when more than
M CIP error responses (non-zero `general_status`) are observed in any 10-second window
per flow (default: 5; strict `>` semantics)

**MITRE ATT&CK for ICS detections (ics-attack-19.1):**

- **T0846 Remote System Discovery** — emitted per flow on the first ENIP ListIdentity
(command 0x0063) frame; one-shot guard per flow. [STORY-134, PR #323, BC-2.17.010]
- **T0888 Remote System Information Discovery** — two detection patterns:
Pattern A: CIP GetAttribute{All,List,Single} request targeting Identity Object
(Class 0x01) in the request path; Pattern B: CIP error-response burst exceeding
`--enip-error-burst-threshold` within a 10-second window. [STORY-134/135, PRs #323/#324,
BC-2.17.014]
- **T0858 Change Operating Mode** — emitted per CIP Stop service (service code 0x07)
request, indicating a controller run-to-stop transition command. [STORY-135, PR #324,
BC-2.17.011]
- **T0816 Device Restart/Shutdown** — emitted per CIP Reset service (service code 0x05)
request. [STORY-135, PR #324, BC-2.17.013]
- **T0836 Modify Parameter** — emitted when CIP write-class services (SetAttributesAll
0x02, SetAttributeList 0x04, SetAttributeSingle 0x10) exceed
`--enip-write-burst-threshold` within a 1-second window per flow. [STORY-135, PR #324,
BC-2.17.012]
- **T0814 Denial of Service** — malformed-frame anomaly; fires when 3 or more
structurally invalid ENIP frames accumulate in a 300-second window per flow. Shared
technique ID with the DNP3/Modbus analyzers. [STORY-137, PR #327, BC-2.17.018]

New `MitreTactic::IcsExecution` enum variant added (TA0104) for T0858 "Change Operating
Mode". MITRE catalog grew from 25 to 28 seeded technique IDs; emitted count grew from
17 to 20 (T0858, T0816, T0846 added to the emitted set). T0846 promoted from
seeded-only to emitted for the first time via ENIP ListIdentity detection.
[STORY-133, PR #320, BC-2.10.008, VP-007]

**Session summary (`enip_summary`):** `summarize()` produces a 7-key JSON object —
`command_distribution`, `total_pdu_count`, `parse_errors`, `write_count`,
`error_count`, `flows_analyzed`, `dropped_findings` — folding both closed and
still-open flows at call time. [STORY-138, PR #329, BC-2.17.021]

**Formal verification and quality assurance:**

- VP-032 Kani proof harnesses Sub-A through Sub-D: `parse_enip_header` all-input
safety, `classify_enip_command` totality, `is_valid_enip_frame` biconditional,
`classify_cip_service` totality. [STORY-130/132, BC-2.17.001–004/007]
- `fuzz_enip_cip_parse` cargo-fuzz harness covering `parse_cpf_items`,
`parse_cip_header`, `parse_cip_request_path`, and `parse_enip_header` — F-P9-002
obligation discharged. [PR #332]
- Full-pipeline E2E tests against real ENIP/CIP pcaps: holdout scenarios HS-110
through HS-122 verified (6 test cases, real-world captures). [PR #333]

### Changed

- **ENIP session summary wire format cleaned up.** The `enip_summary` JSON output uses
the canonical key name `"parse_errors"` (not `"total_parse_errors"`) from day one,
consistent with the lesson learned from the DNP3 rename in v0.10.0. The summary wire
format was further cleaned up to ensure consistent field ordering and null-safety.
[PR #331, BC-2.17.021 Invariant 1]

- **Green-doc-tense CI gate added.** A new CI job (`green-doc-tense-gate`) runs
`bin/check-green-doc-tense` on all tracked source and test files, failing if any
doc-comment or changelog entry uses aspirational tense markers ("will", "planned",
"future") in contexts that assert current behavior. The gate includes a self-test
(`bin/test_check_green_doc_tense.py`) that verifies 10 known-bad and 14 known-good
patterns. [PR #321, b9b2e93]

### Fixed

- **ENIP source-IP attribution corrected.** The per-direction source-IP resolution
in `on_data` was incorrect: it used a port-44818 heuristic that misidentified the
client when the FlowKey's lower port was 44818. Replaced with direction-based
attribution (`Direction::ClientToServer` maps to the TCP initiator; `ServerToClient`
maps to the TCP responder), mirroring the Modbus pattern. Finding `source_ip` fields
now correctly reflect the sending endpoint. [PR #328, AC-139-002]

- **ENIP `summarize()` includes still-open flows.** `summarize()` previously reported
only counters accumulated from closed flows, silently undercounting `total_pdu_count`,
`flows_analyzed`, `parse_errors`, and `command_distribution` whenever flows were still
open at capture end. The summary now folds all still-open `EnipFlowState` entries into
the aggregate at call time (RULING-W61-001). [PR #330, BC-2.17.021 Postcondition 1]

- **Modbus EC-X1: per-direction carry buffer split (`carry_c2s` / `carry_s2c`).**
The Modbus analyzer previously used a single shared carry buffer for both directions, allowing
a response packet's trailing bytes to be spliced into the next request's reassembly window
Expand Down