Monolithic Vibro-Thermal Funicular Data-Center Shell, Three-Tier Waste-Heat TES & Zero-Water Sorption Cooling (v0.1.0).
funi-frame unifies the aska-physical hardware stack—funi-floors, cfrp-truss, fibral-rigidity, venturi-collars, and impedence-analyzers—into a complete, machine-verified AI data-center building exoskeleton and closed-loop thermal plant engineered for 80–250 kW/rack GPU halls that generate high-grade liquid heat (50–60 °C) under strict optical/switch vibration limits (<= 0.0005 g_rms).
- Tilt-Up Concrete + Deep Steel Pratt Roof Trusses Fight Each Other: Standard
280 mmprecast walls (368 kg/m²,U = 2.307 W/(m²·K)when bridged by steel wythe pins,NRC = 0.03reverberant concrete faces) bolted to2.4 m-deep24 msteel trusses (460 kg/m²when ballasted) transmit chiller and generator vibration (loss factor 0.003) straight into$200,000racks (0.137 g_rms >> 0.0005 g_rmsoptical-switch limit), while top-floor-first tenant occupancy creates a top-heavy seismic inverted pendulum (STRUCTURE Magazine; CalcSteel 2026). - Parasitic Chiller Power & Evaporative Water Loss: Conventional chillers (
COP ~ 3.0,PUE = 1.38) consume10–40%of campus electricity and evaporate157.68 million L/yrof potable water per10 MWhall—stranding>3 MWof utility substation capacity that could otherwise power revenue-generating AI racks ($25–$50M/MW-yr, Pandey et al. 2026).
-
24.0 mClear-Span Double-Skin Tied Funicular Radiative Roof (U = 0.1234 W/(m²·K),R-46.0):-
1,480 mmtied barrel-vault cassette (L/f = 17.78) saves920 mmof roof plenum height vs.2,400 mmheavy trusses, cuts roof mass by52.32%(219.32vs.460 kg/m²), achievesL/2,044service stiffness (11.74 mmvs. rolled steelIPE 600failure atL/71.6), resists6.2 kPatornado suction viacfrp-trusscolumn tie-downs (783.0 >= 307.0 kN) without ballast, and delivers93.0 W/m²daytime radiative sky cooling (8–13 µmwindow).
-
-
Carbon-TRC + Poraver Expanded-Glass +
mPCMSandwich Shear Walls (U = 0.1316 W/(m²·K),R-43.2):-
45°CFRP wythe shear grids eliminate metallic thermal bridges (17.5xlowerU-value than steel-pinned PCSPs at2.307 W/(m²·K)), cut wall mass by56.61%(159.66vs.368 kg/m²), absorb interior server/CDU fan roar via Helmholtz-slotted Poraver expanded-glass concrete (NRC = 0.72,-10.97 dBAhall noise drop,STC 60.1 dBgenerator masking), and provide28.30 minpassive UPS-to-generator thermal ride-through (28 °Cmicro-encapsulated PCM) vs.1.78 minfor unbuffered cold-aisle air.
-
-
Three-Stage Broadband Vibration Isolation Cascade (
0.000090 <= 0.000500 g_rms):- SymPy proves hysteretic
Fe-Mn-Si+CLDdamping rolls off at$O(\omega^{-2})$ (-40 dB/dec) without high-frequency viscous damper lock-up$O(\omega^{-1})$ . CombiningFe-Mn-Siring-spring equipment plinths (4.5 Hz,eta = 0.16),±45°CFRP viscoelastic Constrained-Layer Damped (CLD,9.2 Hz,eta = 0.12) bay seats, andFe-SMAnodal collar breaks achieves-63.69 dBimprovement over steel (17.91%of the0.0005 g_rmsoptical-switch ceiling).
- SymPy proves hysteretic
-
Top-Down Seismic Cellular Box & Zero-Dust White Space (
ASCE 7Risk Category IV):- Cuts whole-shell structural dead mass by
64.83%(1,431.4vs.4,069.8 tonnes), saves2.02 mof building height, reduces seismic base shear by44.23%, holds top-down loaded story drift to0.563% <= 1.00%Immediate Occupancy limit (unbraced heavy frames hit4.359%), and seals overhead concrete inside stay-in-place composite pans (0spalling dust).
- Cuts whole-shell structural dead mass by
-
Three-Tier Waste-Heat Thermal Energy Storage (
PCM+ Crushed Basalt +ATES/RTES+ Energy Piles):- Pairs
83.33 m³salt-hydrateHS24PCMskids (30.0vs.11.5 kWh_th/m³water =-61.67%tank volume for15-min2.5 MWh_thride-through),88.68 m³(20 MWh_th)500 Kcrushed-basalt packed beds (225.5 kWh_th/m³,$14,046mineral cost at$0.014/kWh_thannualized capex—4.86xlower than Li-ion),200thermo-active foundation piles (250 kW_th), and coastalATES/ deep brackishRTESwellfields (COP 10–54).
- Pairs
-
Closed-Loop Sorption Cooling (
PUE = 1.074,WUE = 0.000 L/kWh,+3.06 MWFreed Compute Power):- SymPy proves self-cooling above
$\alpha_{\text{liq}}^* = 1/(1 + \text{COP}_{\text{ads}}) = 61.73%$ :85%ASHRAE W45(58 °C) cold-plate return directly regenerates solid-sorbent silica-gel adsorption chillers (2.419 MW_thdrive ->1.50 MW_thRDHx cooling, zero heat pump), cutting annual cooling electricity by85.05%, saving157.68 million L/yrof potable water, and freeing3.06 MWof utility power ($76.62M–$153.2M/yrunlocked AI compute revenue).
- SymPy proves self-cooling above
python3 verify.pyVerifies four SymPy symbolic theorems and 12/12 must-fail controls against results/certificate.json. Full engineering monographs, inter-agent handoff, negative findings, and roadmap live in docs/ENGINEERING_STUDIES.md, HANDOFF.md, and CHANGELOG.md.
- Architect & Human Sign-Off: Shahid Arifuddin (
@abu-aska) - Foundational
Foundation-0Lineage: Ahraz Arifuddin (@ahrazzle) - Autonomous Engineering Capture: Google Gemini (per
ETHOS.md).