Skip to content

kona-engine: consolidate safe attributes only on top of the local-safe head #24130

Open

Description

@einar-oplabs

Summary

kona-node's engine can apply safe attributes after an engine reset even though they were derived before it. It does this even when they do not build on the current local-safe head. Local-safe then jumps past blocks that derivation never confirmed, the SafeDB never records them, and later answers for that range are wrong.

Found by the safedb-reviewer pass for #23473 on develop at 7f7abd37fd.

Path

  1. EngineActorRequest::ProcessSafeL2Signal queues a ConsolidateTask without any check (rust/kona/crates/node/service/src/actors/engine/actor.rs:328-336).
  2. begin_reset clears the task queue only when no reset is already pending (actor.rs:116-123). Safe signals that arrive while the reset is pending stay queued.
  3. Consolidation compares the attributes with the canonical block at that height (rust/kona/crates/node/engine/src/attributes.rs:299), not with the current local-safe head.
  4. After a reset to R < P, attributes for P+1 (parent P) still consolidate, and local-safe jumps from R to P+1. Derivation is waiting on the attributes for R+1. Its match check fails, so it records nothing (rust/kona/crates/node/service/src/actors/derivation/actor/core.rs:402-409), but it still adopts P+1.

op-node drops attributes whose parent is not the pending-safe head, and resets on a parent conflict (op-node/rollup/attributes/attributes.go:155-182).

Impact

Blocks R+1..P+1 are never recorded:

  • superroot_atTimestamp reports a later required L1 for those blocks, so op-challenger's super trace provider treats the claim as an invalid transition.
  • optimism_safeHeadAtL1Block over that L1 range returns R, which is too low, and the output trace clamps there.

Local-safe also advances over blocks that derivation did not confirm. That is a derivation-level concern beyond the SafeDB.

Status: every step was checked in code. The cross-actor ordering has not been reproduced.

Fix

  • In the kona engine, consolidate attributes only when attributes.parent is the local-safe head, and handle a parent conflict as op-node does.
  • Consider dropping safe signals that arrive while a reset is pending.

Acceptance criteria

  • Attributes derived before a reset cannot advance local-safe past an unconfirmed range.
  • A regression test delivers attributes derived before a reset after it, and asserts SafeDB history below the tip, including l1_at_safe_head inside the affected range. It fails without the fix.
  • A safedb-reviewer re-run on the change reports I2 and I3 holding.