7 changes: 7 additions & 0 deletions AGENTS.md
Original file line number Diff line number Diff line change
Expand Up @@ -78,6 +78,13 @@ in Ring & sync sends mode 3 and then reconnects (`RingSyncEngine.restartDevice`)
without a verified reboot, it only reconnects. YCBT and LuckRing still have no reset; add one
the same way, from their own decompiles.

The same decompile shows the app passes the ring's BP and sugar through unchanged. The ring
computes them from the profile (`0x02`) and a cuff reference (`0x33`, default 120/80, write-only).
That reference is sent to the ring, **never added to readings**. The ring's 15-minute log of those
estimates is `0x55`, gated on `0x20` bit 83. After each day's heart rate, `JringHistorySync`
imports it together with offline temperature (`0x39`, bit 10) and offline SpO₂ (`0x40`, bit 81),
in the vendor's order. A unit that sets bit 10 is granted TEMPERATURE at runtime. Details: `docs/jring-56ff-plan.md`, "What the vendor app does with BP and sugar".

## Colmi/Yawell OS-bonding is a hand-curated allowlist — not "match QRing exactly"

**This is the one rule in this file most likely to get silently reverted by a future "generalize
Expand Down
4 changes: 4 additions & 0 deletions app/src/main/assets/i18n/pt-BR.json
Original file line number Diff line number Diff line change
Expand Up @@ -339,6 +339,8 @@
"Café com leite": "Café com leite",
"Caipirinha": "Caipirinha",
"Calibrate": "Calibrar",
"Calibrated to your cuff reading of {0}/{1} mmHg. The ring adjusts its estimates to it.": "Calibrado com sua medição de manguito de {0}/{1} mmHg. O anel ajusta as estimativas a ela.",
"Calibrated to your meter reading of {0}. The app shifts the ring's estimate to match it.": "Calibrado com sua medição de glicosímetro de {0}. O app ajusta a estimativa do anel para bater com ela.",
"Calibrated ✓ (offset %+.0f mg/dL)": "Calibrado ✓ (ajuste %+.0f mg/dL)",
"Calibration": "Calibração",
"Calibration cleared": "Calibração apagada",
Expand Down Expand Up @@ -1201,6 +1203,8 @@
"Not all three hold, so LAM doesn't apply now.": "Nem todas as três condições valem, então a LAM não se aplica agora.",
"Not allowed to read: ": "Sem permissão para ler: ",
"Not breastfeeding": "Não estou amamentando",
"Not calibrated. Enter a meter or lab reading to shift the ring's estimate to match it.": "Não calibrado. Informe uma medição de glicosímetro ou de laboratório para ajustar a estimativa do anel.",
"Not calibrated. Enter a reading from a validated cuff so the ring adjusts its estimates to you.": "Não calibrado. Informe uma medição de um manguito validado para o anel ajustar as estimativas a você.",
"Not connected": "Não conectado",
"Not downloaded yet": "Ainda não baixado",
"Not enough data for this period.": "Dados insuficientes para este período.",
Expand Down
21 changes: 14 additions & 7 deletions app/src/main/java/com/pulseloop/ring/JringDriver.kt
Original file line number Diff line number Diff line change
Expand Up @@ -46,12 +46,14 @@ object JringCoordinator : WearableCoordinator {
WearableCapability.REALTIME_HEART_RATE,
WearableCapability.FIND_DEVICE,
WearableCapability.FACTORY_RESET, // 0x0E mode 4, the vendor's "Factory reset"
// NOTE: No TEMPERATURE — the Jring (SR08-class PPG ring) has no skin-temperature
// sensor. In the official app temperature is gated by the 0x20 capability bit
// FUNCTION_TEMPERATURE (zArr[10]), which these rings do not set; it exists in the
// shared SDK only for smartwatch variants.
// NOTE: No TEMPERATURE in the baseline. The vendor gates it on the 0x20 bit
// FUNCTION_TEMPERATURE (zArr[10]), and SR08-class rings don't set it. Some units do
// (firmware 003A002AV138 does), so it is granted per unit through
// [bitmapGatedCapabilities] when the 0x20 reply sets the bit (RingDecoder.decodeBandFunction).
)

override val bitmapGatedCapabilities: Set<WearableCapability> = setOf(WearableCapability.TEMPERATURE)

override val iconSystemName = "circle.hexagongrid.circle.fill"

override fun makeDriver(writer: RingCommandWriter): WearableDriver = JringDriver(writer)
Expand Down Expand Up @@ -125,8 +127,8 @@ class JringSyncEngine(
private val encoder = RingEncoder

/** The ring's self-reported feature bits (0x20 reply), or `null` if it never answered.
* Nothing branches on these yet — captured so a future offline-history sync chain can gate
* its extra per-day queries once the bit ordering is confirmed against real hardware. */
* Bit 83 gates the per-day 0x55 sensor log ([JringHistorySync.sensorHistory]); the vendor
* builds the same array least-significant bit first (`utils.m.b`, mask {1,2,4,…,128}). */
private var bandCapabilities: JringBandCapabilities? = null

override fun runStartup() {
Expand Down Expand Up @@ -193,7 +195,12 @@ class JringSyncEngine(
0 -> if (event.state == 0) writer?.enqueue(encoder.makeBindAppStartCommand()) // INIT → APP_START
2 -> writer?.enqueue(encoder.makeBindSuccessCommand()) // ACK → SUCCESS
}
is RingDecodedEvent.BandFunction -> bandCapabilities = event.capabilities
is RingDecodedEvent.BandFunction -> {
bandCapabilities = event.capabilities
historySync.sensorHistory = event.capabilities.hasPressureHistory
historySync.oxygenHistory = event.capabilities.hasOxygenOfflineHistory
historySync.temperatureHistory = event.capabilities.hasTemperature
}
else -> {}
}
}
Expand Down
80 changes: 75 additions & 5 deletions app/src/main/java/com/pulseloop/ring/JringHistorySync.kt
Original file line number Diff line number Diff line change
Expand Up @@ -34,7 +34,9 @@ import kotlinx.coroutines.launch
* settle/stall timers are only its fallback.
*
* Per day: `0x10/offset` → the day's activity+sleep stream → settles → `0x16/offset` → the day's
* HR stream → `0xFF` (or settles) → next day. A day that answers nothing at all still gets its HR
* HR stream → `0xFF` (or settles) → each offline log the ring advertises, in the vendor's order:
* temperature `0x39` ([temperatureHistory]), SpO₂ `0x40` ([oxygenHistory]), BP/stress/sugar/HRV
* `0x55` ([sensorHistory]); each ends on its 23:45 slot or when it settles → next day. A day that answers nothing at all still gets its HR
* request, because `16 00` was previously sent unconditionally and today's HR must not become
* collateral of a silent `0x10`.
*
Expand All @@ -53,8 +55,23 @@ class JringHistorySync(
private val encoder = RingEncoder
private val scope = CoroutineScope(Dispatchers.Default + SupervisorJob())

/** The two legs of one day, in the order the vendor asks for them. */
private enum class Leg { ACTIVITY, HEART_RATE }
/** The legs of one day, in the order the vendor asks for them (`FragmentMain`'s
* `ACTION_NOTIFY_BLE_SYNC_DATA_BY_DAY_END` chain: 1 → 2 → 12 → 13 → advanced sensor). */
private enum class Leg { ACTIVITY, HEART_RATE, TEMPERATURE, OXYGEN, SENSOR }

/** Offline skin temperature (0x39, `getDataByDay(12, day)`), gated on 0x20 bit 10. */
@Volatile var temperatureHistory: Boolean = false

/** Offline SpO₂ (0x40, `getDataByDay(13, day)`), gated on 0x20 bit 81. */
@Volatile var oxygenHistory: Boolean = false

/**
* Whether to ask each day for the ring's offline sensor log (0x55: BP, stress, sugar, HRV).
* Set from the 0x20 capability bit 83 ([JringBandCapabilities.hasPressureHistory]), which is
* the vendor's own gate (`FragmentMain`, `FUNCTION_HAS_PRESSURE` → `getAdvSensorOfflineData`).
* Read when a day's heart-rate leg ends, by which time the 0x20 reply has long arrived.
*/
@Volatile var sensorHistory: Boolean = false

private var queue = mutableListOf<Int>()
private var currentDay: Int? = null
Expand Down Expand Up @@ -111,9 +128,24 @@ class JringHistorySync(
if (leg != Leg.HEART_RATE) return
// The one genuine end-of-stream signal in this protocol — take it rather than
// waiting out the settle window.
if (data.size >= 2 && (data[1].toInt() and 0xFF) == HR_SYNC_FINISHED) advance()
if (data.size >= 2 && (data[1].toInt() and 0xFF) == HR_SYNC_FINISHED) nextLegAfter(Leg.HEART_RATE)
else restartSettle()
}
OPCODE_TEMPERATURE -> if (leg == Leg.TEMPERATURE) restartSettle()
// The vendor's "getdayabyday failed" reply: the ring has no temperature log for that
// day (`BluetoothLeService` "b9" → `onGetDataByDayEnd(12, 0)`). Move on.
OPCODE_DAY_FAILED -> if (leg == Leg.TEMPERATURE) nextLegAfter(Leg.TEMPERATURE)
OPCODE_OXYGEN -> {
if (leg != Leg.OXYGEN) return
// 15 one-minute readings per frame; the frame holding 23:45 is the day's last.
if (holdsLastSlot(data, slots = 15, stepMinutes = 1)) nextLegAfter(Leg.OXYGEN) else restartSettle()
}
OPCODE_SENSOR -> {
if (leg != Leg.SENSOR) return
// The vendor ends the day's log when a slot lands on 23:45 (the last of the day)
// and otherwise on its 2000 ms idle timer; a past day ends here, today settles.
if (holdsLastSlot(data, slots = 3, stepMinutes = 15)) advance() else restartSettle()
}
}
}

Expand Down Expand Up @@ -143,14 +175,46 @@ class JringHistorySync(
armStall()
}

/**
* After [done], ask for the day's next offline log the ring keeps, in the vendor's order, or
* move to the next day. Each is gated on the 0x20 bit the vendor gates it on.
*/
private fun nextLegAfter(done: Leg) {
val day = currentDay ?: return
val optional = listOf(
Leg.TEMPERATURE to temperatureHistory,
Leg.OXYGEN to oxygenHistory,
Leg.SENSOR to sensorHistory,
)
val next = optional.firstOrNull { (l, on) -> on && l.ordinal > done.ordinal }?.first
if (next == null) { advance(); return }
cancelTimers()
leg = next
writer?.enqueue(when (next) {
Leg.TEMPERATURE -> encoder.makeTemperatureHistoryQueryCommand(dayOffset = day)
Leg.OXYGEN -> encoder.makeOxygenHistoryQueryCommand(dayOffset = day)
else -> encoder.makeSensorHistoryQueryCommand(dayOffset = day)
})
armStall()
}

/** A leg's stream went quiet: hand over to the next leg, or the next day. */
private fun legSettled() {
when (leg) {
Leg.ACTIVITY -> beginHeartRateLeg()
Leg.HEART_RATE -> advance()
else -> nextLegAfter(leg)
}
}

/** Whether a frame's slots include 23:45, read in the ring's own local clock. */
private fun holdsLastSlot(data: ByteArray, slots: Int, stepMinutes: Int): Boolean {
if (data.size < 5) return false
val raw = (data[1].toLong() and 0xFF) or ((data[2].toLong() and 0xFF) shl 8) or
((data[3].toLong() and 0xFF) shl 16) or ((data[4].toLong() and 0xFF) shl 24)
val minuteOfDay = Math.floorMod(raw, 86_400L) / 60
return (0 until slots).any { minuteOfDay + it.toLong() * stepMinutes == LAST_SLOT_MINUTE.toLong() }
}

// MARK: - Timers

/** Data arrived: the stall no longer applies, and the quiet period starts over. */
Expand Down Expand Up @@ -193,6 +257,12 @@ class JringHistorySync(
private const val OPCODE_ACTIVITY = 0x10
private const val OPCODE_SLEEP = 0x11
private const val OPCODE_HEART_RATE = 0x16
private const val OPCODE_SENSOR = 0x55
private const val OPCODE_TEMPERATURE = 0x39
private const val OPCODE_OXYGEN = 0x40
private const val OPCODE_DAY_FAILED = 0xB9
/** 23:45 — the vendor's end-of-day slot for the 0x55 log. */
private const val LAST_SLOT_MINUTE = 23 * 60 + 45
/** `0x16` subtype `0xFF` — "sync finished" (`RingDecoder.decodeHeartRateHistory`). */
private const val HR_SYNC_FINISHED = 0xFF
}
Expand Down
110 changes: 106 additions & 4 deletions app/src/main/java/com/pulseloop/ring/RingDecoder.kt
Original file line number Diff line number Diff line change
Expand Up @@ -51,12 +51,16 @@ class RingDecoder(private val clock: JringClock? = null) {
0x11 -> listOf(decodeSleepTimeline(bytes))
0x14 -> listOf(decodeLiveHeartRate(bytes, now))
0x16 -> decodeHeartRateHistory(bytes) // multi-packet protocol
0x20 -> listOf(decodeBandFunction(bytes))
0x20 -> decodeBandFunction(bytes)
0x24 -> decodeCombinedSensor(bytes, now) // 5 metrics in one packet
0x27 -> listOf(RingDecodedEvent.HeartRateComplete(_timestamp = now))
0x28 -> listOf(RingDecodedEvent.Spo2Complete(_timestamp = now))
0x3F -> listOf(decodeSpo2Result(bytes, now))
0x4B -> listOf(decodeBindNotify(bytes)) // ring-side bind/unbind handshake
0x55 -> decodeSensorHistory(bytes) // offline BP/stress/sugar/HRV, 3× 15-min slots
0x39 -> decodeTemperatureHistory(bytes) // offline skin temperature, 3× 5-min slots
0x40 -> decodeOxygenHistory(bytes) // offline SpO₂, 15× 1-min readings
0xB9 -> listOf(RingDecodedEvent.HistorySyncProgress(stage = "day_unavailable"))
0xF6 -> listOf(decodeFirmwareVersion(bytes))
else -> listOf(RingDecodedEvent.Unknown(commandId = packet.commandId, raw = bytes))
}
Expand Down Expand Up @@ -269,6 +273,97 @@ class RingDecoder(private val clock: JringClock? = null) {
}
}

// ── 0x55: Offline sensor history ──────────────────────────────────────

/**
* The ring's own every-15-minutes log of its estimates, from the vendor SDK's 0x55 branch
* (`BluetoothLeService`, `str3 == "55"` → `onGetAdvSensorOfflineData`):
*
* [0] 0x55, [1..4] slot time (u32 LE, the ring's local-wall-clock epoch, see [JringClock]),
* then three slots of five bytes at 5, 10, 15:
* systolic, diastolic, stress, blood sugar (mmol/L × 10), HRV.
* Slot n is 15 minutes after slot 0.
*
* The vendor app stores BP only when both halves are non-zero and every other value only when
* non-zero (`DupMainActivity.onGetAdvSensorOfflineData`), with no other change; so do we.
* These are the same figures the live 0x24 measurement returns, so they are estimates, and
* the UI labels them as such.
*/
private fun decodeSensorHistory(bytes: ByteArray): List<RingDecodedEvent> {
if (bytes.size < 20) return listOf(unknown(0x55, bytes))
val base = ringDate(u32le(bytes, 1).toLong())
return buildList {
for (slot in 0 until 3) {
val o = 5 + slot * 5
val at = base.plusSeconds(slot * 15L * 60L)
val sys = bytes[o].toInt() and 0xFF
val dia = bytes[o + 1].toInt() and 0xFF
val stress = bytes[o + 2].toInt() and 0xFF
val sugar = bytes[o + 3].toInt() and 0xFF
val hrv = bytes[o + 4].toInt() and 0xFF
if (sys > 0 && dia > 0) {
add(RingDecodedEvent.HistoryMeasurement(MeasurementKind.BLOOD_PRESSURE_SYSTOLIC, sys.toDouble(), at))
add(RingDecodedEvent.HistoryMeasurement(MeasurementKind.BLOOD_PRESSURE_DIASTOLIC, dia.toDouble(), at))
}
if (stress > 0) add(RingDecodedEvent.HistoryMeasurement(MeasurementKind.STRESS, stress.toDouble(), at))
if (sugar > 0) add(RingDecodedEvent.HistoryMeasurement(MeasurementKind.BLOOD_SUGAR, (sugar / 10.0) * 18.016, at))
if (hrv > 0) add(RingDecodedEvent.HistoryMeasurement(MeasurementKind.HRV, hrv.toDouble(), at))
}
// A frame of empty slots still belongs to the stream: say so, so it isn't logged as
// `unknown` and exported in clear (AGENTS.md, diagnostics masking).
if (isEmpty()) add(RingDecodedEvent.HistorySyncProgress(stage = "sensor_history"))
}
}

// ── 0x39: Offline temperature ─────────────────────────────────────────

/**
* The vendor SDK's "39" branch → `onGetDataByDay(12, t, surface, body)`:
* `[1..4]` slot time (ring-local epoch), then three 5-minute slots of four bytes at 5, 9, 13:
* surface temperature (u16 LE, °C × 100) and body temperature (u16 LE, °C × 100).
*
* Only the surface value is stored, as [MeasurementKind.TEMPERATURE]: that is what the card
* shows for every other ring (skin temperature). The "body" figure is the ring's own model of
* core temperature, a second estimate on top of the first, and is left out. Out of 25–45 °C
* (0 included) means no reading.
*/
private fun decodeTemperatureHistory(bytes: ByteArray): List<RingDecodedEvent> {
if (bytes.size < 20) return listOf(unknown(0x39, bytes))
val base = ringDate(u32le(bytes, 1).toLong())
return buildList {
for (slot in 0 until 3) {
val o = 5 + slot * 4
val surface = ((bytes[o].toInt() and 0xFF) or ((bytes[o + 1].toInt() and 0xFF) shl 8)) / 100.0
if (surface in 25.0..45.0) add(RingDecodedEvent.HistoryMeasurement(
MeasurementKind.TEMPERATURE, surface, base.plusSeconds(slot * 300L),
))
}
if (isEmpty()) add(RingDecodedEvent.HistorySyncProgress(stage = "temperature_history"))
}
}

// ── 0x40: Offline SpO₂ ────────────────────────────────────────────────

/**
* The vendor SDK's "40" branch → `onGetOxygenOfflineData(t, value)`: `[1..4]` slot time
* (ring-local epoch), then fifteen one-minute readings at bytes 5–19, one byte each, percent.
* The vendor keeps 1–100 (`FragmentMain`, type 13); we keep 70–100, the band used for every
* other ring's SpO₂, so a stray low byte can't read as a desaturation.
*/
private fun decodeOxygenHistory(bytes: ByteArray): List<RingDecodedEvent> {
if (bytes.size < 20) return listOf(unknown(0x40, bytes))
val base = ringDate(u32le(bytes, 1).toLong())
return buildList {
for (i in 0 until 15) {
val v = bytes[5 + i].toInt() and 0xFF
if (v in 70..100) add(RingDecodedEvent.HistoryMeasurement(
MeasurementKind.SPO2, v.toDouble(), base.plusSeconds(i * 60L),
))
}
if (isEmpty()) add(RingDecodedEvent.HistorySyncProgress(stage = "oxygen_history"))
}
}

// ── 0x3F: SpO₂ Result ─────────────────────────────────────────────────

private fun decodeSpo2Result(bytes: ByteArray, now: Instant): RingDecodedEvent {
Expand Down Expand Up @@ -317,9 +412,16 @@ class RingDecoder(private val clock: JringClock? = null) {

// ── 0x20: Capability Bitmask ─────────────────────────────────────────

private fun decodeBandFunction(bytes: ByteArray): RingDecodedEvent {
if (bytes.size < 2) return unknown(0x20, bytes)
return RingDecodedEvent.BandFunction(JringBandCapabilities(bytes.copyOfRange(1, bytes.size)))
private fun decodeBandFunction(bytes: ByteArray): List<RingDecodedEvent> {
if (bytes.size < 2) return listOf(unknown(0x20, bytes))
val caps = JringBandCapabilities(bytes.copyOfRange(1, bytes.size))
// A unit that sets bit 10 has a temperature log the app can read (0x39), so it gets the
// card; the family baseline leaves TEMPERATURE out because most of these rings don't.
val reported = buildSet { if (caps.hasTemperature) add(WearableCapability.TEMPERATURE) }
return listOfNotNull(
RingDecodedEvent.BandFunction(caps),
reported.takeIf { it.isNotEmpty() }?.let { RingDecodedEvent.SupportFunctions(it) },
)
}

// ── Helpers ───────────────────────────────────────────────────────────
Expand Down
Loading
Loading