You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Yes, I would like to switch phase modes also, with API v1. The parameter "pha" seems to be read-only. Is this true?
The parameter "fsp" is not available for my Hardware (V2), correct?
Question goes to @peterpoetzi
FYI, I'm using API v2 with the psm parameter (r/w) to switch between 3 and 1 phase using node red. As soon as the available solar power exceeds some percentage of the demand for all currently charging stations, I switch from 1 to 3-phase, with some hysteresis to switch back. Moreover, I always force 3-phase charging when the cheap night energy tariff starts (here at 9 pm). The go-e are connected to the grid with rotating phases to minimize asymmetric phase load when multiple cars are charging simultaneously in one-phase mode.
Activity
archie-bal commentedon Sep 8, 2022
Yes, I would like to switch phase modes also, with API v1. The parameter "pha" seems to be read-only. Is this true?
The parameter "fsp" is not available for my Hardware (V2), correct?
Question goes to @peterpoetzi
marcelgsteiger commentedon Feb 8, 2023
FYI, I'm using API v2 with the psm parameter (r/w) to switch between 3 and 1 phase using node red. As soon as the available solar power exceeds some percentage of the demand for all currently charging stations, I switch from 1 to 3-phase, with some hysteresis to switch back. Moreover, I always force 3-phase charging when the cheap night energy tariff starts (here at 9 pm). The go-e are connected to the grid with rotating phases to minimize asymmetric phase load when multiple cars are charging simultaneously in one-phase mode.