Watchdog / failsafe current limit for external energy management #343

Description

@fuchs-1978

Hi,
I use go-e chargers with an external energy management system (ioBroker) which dynamically controls the charging current via the API.

For grid-control use cases such as §14a EnWG / EEBUS LPC, it would be very useful to have a watchdog directly in the charger.
The idea would be:

An external EMS periodically refreshes a watchdog/heartbeat via API.
If no heartbeat is received within a configurable timeout, e.g. 30 or 60 seconds, the charger automatically switches to a configurable failsafe state.

Possible failsafe actions:
set charging current to a configured minimum, e.g. 6 A
optionally stop charging completely
optionally switch to a predefined phase/current configuration

Example:
normal operation: external EMS allows 16 A
watchdog timeout: 60 s
failsafe current: 6 A

EMS/network communication fails
charger automatically reduces to 6 A without depending on the external controller
This would be especially helpful when multiple controllable loads share a dynamic grid limit. A charger may temporarily receive a higher limit, but if communication to the EMS breaks down, it should not indefinitely keep that last higher value.

Ideally the API could expose:
watchdog enable/disable
watchdog timeout
failsafe current
failsafe action
watchdog status / last heartbeat

Would something like this be possible in the firmware/API?

Activity

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions