Custom component for Home Assistant that connects to a Hoval heat pump controller via Modbus TCP and exposes it as regular Home Assistant entities — sensors, a domestic hot water (DHW) control, and climate entities for up to 3 room heating circuits.
Setup is done entirely through the Home Assistant UI — no YAML required.
This is an unofficial, community-developed integration and is not affiliated with, endorsed by, or supported by Hoval. "Hoval" and any related trademarks are the property of their respective owner.
This software is provided "as is", without warranty of any kind, and is used entirely at your own risk. The author(s) assume no liability for any damage, data loss, equipment malfunction, or other harm resulting from the use of this integration, including but not limited to unintended interaction with your heat pump's Modbus interface.
For architecture details, implementation notes, and instructions on adapting this integration to a different heat pump model, see DEVELOPER.md.
This integration requires pymodbus version 3.11.0 or newer (3.10.0
had known issues and is excluded), which Home Assistant installs
automatically. If you're on an older, manually managed Python
environment, make sure pymodbus>=3.11.0 is installed.
Requires HACS to be installed. Clicking the button above adds this repository to HACS on your Home Assistant instance; confirm the dialog there, then install the integration from HACS and restart Home Assistant.
- Copy
custom_components/hoval_unofficialinto theconfig/custom_components/directory of your Home Assistant instance. - Restart Home Assistant.
- Settings → Devices & Services → Add Integration → search for "Hoval Heat Pump Integration (unofficial)".
- Enter in the dialog:
- Name for this heat pump (used as the device name in HA)
- IP address of the controller
- Port (default: 502)
- Modbus device ID (default: 1)
- optional: polling interval in seconds
Home Assistant tests the connection directly during setup. If it fails, an error message is shown in the dialog.
You can change the IP address, port, name, or device ID later via the entry's three-dot menu → Reconfigure.
- Sensors — outdoor temperature, flow/return temperatures, heat quantities, operating hours, COP, and a translated status sensor (shows the controller's current status as readable text in your HA language, e.g. "Heating mode" / "Defrost" / "Frost protection").
- Domestic hot water (DHW) — a
water_heaterentity showing tank temperature, target temperature, and operating mode. - Room heating circuits (HC1/HC2/HC3) —
climateentities for up to three heating circuits. Only HC1 is shown by default; if you have additional circuits, enable HC2/HC3 under Settings → Devices & Services → this integration → Entities (they're created but hidden by default, since not everyone has more than one circuit).
Each circuit has 5 operating modes, mapped onto Home Assistant's climate controls as follows:
| Controller mode | Home Assistant |
|---|---|
| Off | Off |
| Constant | Heat |
| Week 1 / Week 2 / Eco | Auto, with the specific program selected via the preset dropdown |
- Setting a target temperature only works in Heat ("Constant") or in Auto with the Eco preset selected — Week 1/Week 2 are driven by the controller's own schedule and can't be overridden directly. In those modes the temperature control still shows the current setpoint, just without the ability to change it.
- Switching to Auto remembers whichever program (Week 1/Week 2/Eco) was last active, so you don't need to re-select it every time.
- After changing a mode or temperature, it can take up to ~30 seconds
for the Hoval controller to actually apply the change — the display
updates immediately to show what you requested, and a
mode_change_pending/temperature_change_pendingattribute (visible under "Attributes" in the entity's more-info dialog) showstruewhile waiting for the controller to confirm it. - After changing the mode (e.g. switching between Constant and Eco), the displayed target temperature can take a few minutes to catch up with the new mode's actual setpoint — longer than the ~30 seconds above. This is because the target temperature shown always reflects whichever setpoint the controller currently considers "active", and it can take the controller a little while internally to switch over to the new mode's setpoint after you change modes. This isn't something the integration can speed up or track precisely, since it's a side effect of the mode change rather than a change you request directly.
By default, a heating circuit's current room temperature isn't shown (only the target temperature). You can change this per circuit under the entry's three-dot menu → Configure:
- Don't show a current temperature (default)
- Read from Heat Pump — uses the controller's own room sensor, if one is installed for that circuit
- Use a Home Assistant entity — pick any existing temperature sensor (e.g. a separate smart thermostat in that room) to use instead
Same 5 modes as the heating circuits (Off / Constant / Week 1 / Week 2 / Eco), with Constant and Eco each having their own target temperature. Setting a temperature only works in those two modes, same restriction and reasoning as for the heating circuits above — including the note above that after switching between Constant and Eco, the displayed target temperature can take a few minutes to catch up with the new mode's actual setpoint.
Available under the entry's three-dot menu → Configure:
- Polling interval (seconds) — how often the integration reads data from the controller.
- Room temperature source — see above, configurable per heating circuit.
Changing any option takes effect immediately, without needing to remove and re-add the integration.
Some text still shows in English after switching Home Assistant to a different language, or vice versa. Custom integration translations are cached by Home Assistant. Try, in order:
- Settings → System → Restart (not just reloading the integration).
- A hard refresh in your browser (Ctrl/Cmd+Shift+R), or fully closing and reopening the mobile app.
Connection fails during setup. Double-check the IP address, port, and that the controller's Modbus interface is enabled and reachable from your Home Assistant instance (same network / no firewall blocking the port).
Connection fails, or works intermittently, when something else is also
talking Modbus to the heat pump (e.g. you also have the heat pump set
up via Home Assistant's built-in modbus: YAML integration, or any other
tool/script polling it). The Hoval controller's Modbus server only
accepts a single client connection at a time — a second connection
attempt will fail as long as the first one is still open. Symptoms
include this integration failing to connect, or connections dropping and
reconnecting unpredictably.
The fix is to put a Modbus TCP proxy in front of the controller, so
multiple consumers can share a single real connection to it:
ha-modbusproxy. Point the
proxy at the heat pump's real IP address, then point both this
integration and any YAML-based modbus: config (if you still need it)
at the proxy's IP address/port instead of the heat pump directly.
Security note: since the proxy forwards whatever it receives to the heat pump's Modbus interface, restrict access to it with firewall rules (e.g. only allow your Home Assistant server's IP) so it doesn't become an open, unauthenticated gateway to your heat pump's Modbus interface for anyone else on your network.
- Cooling (active cooling mode) isn't currently implemented. The author doesn't have a cooling-capable installation to test against — contributions welcome if you do.
- Smart Grid control (e.g. SG-Ready style external control inputs) isn't currently exposed by this integration.
- Christian Kropf — for providing the initial YAML Modbus configuration this integration was built from.
- Max Stoll — for support and help, especially regarding the heat pump and Modbus specifics.
This integration was developed with AI assistance.