Skip to content

Conversation

@haiyangz
Copy link
Owner

No description provided.

Our NIC can have up to 4 RX packets on 1 CQE. To support this feature,
check and process the type CQE_RX_COALESCED_4. The default setting is
disabled, to avoid possible regression on latency.

And add ethtool handler to switch this feature. To turn it on, run:
  ethtool -C <nic> rx-frames 4
To turn it off:
  ethtool -C <nic> rx-frames 1

Signed-off-by: Haiyang Zhang <haiyangz@microsoft.com>
For RX CQEs with type CQE_RX_COALESCED_4, to measure the coalescing
efficiency, add counters to count how many CQEs contain 2, 3, 4 packets
respectively.
Also, add a counter for the error case of first packet with lenth == 0.

Signed-off-by: Haiyang Zhang <haiyangz@microsoft.com>