21 changes: 18 additions & 3 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -129,15 +129,30 @@ Conservative update policy with n-0.1 minor version pinning. Keeps you one minor
**Commands:**

```bash
sudo ./proxmox-update-policy.sh enable # Enable with UI patches
sudo ./proxmox-update-policy.sh enable --no-ui # Enable without UI patches
sudo ./proxmox-update-policy.sh disable # Disable and restore UI
sudo ./proxmox-update-policy.sh enable # Pin + suppress warnings
sudo ./proxmox-update-policy.sh enable --no-ui # Pin only, keep warnings
sudo ./proxmox-update-policy.sh ui-only # Suppress warnings, pin nothing
sudo ./proxmox-update-policy.sh ui-disable # Restore warnings, keep pinning
sudo ./proxmox-update-policy.sh disable # Remove both
sudo ./proxmox-update-policy.sh status # Show policy and versions
sudo ./proxmox-update-policy.sh update # Refresh pinning
sudo ./proxmox-update-policy.sh cron-enable # Install daily cron
sudo ./proxmox-update-policy.sh cron-disable # Remove cron
```

**Pinning and the UI customisation are independent.** A host can hold packages
back, suppress the subscription warnings, both, or neither:

| Want | Command |
|---|---|
| Both | `enable` |
| Pin only, keep the warnings | `enable --no-ui` |
| Warnings gone, track latest | `ui-only` |
| Neither | `disable` |

`ui-only` is the right choice for a host that should stay current -- a lab or
a personal box -- but without Proxmox telling you off about it on every login.

**UI customisations:**

When enabled, the web interface reports the update policy that is actually in
Expand Down
49 changes: 48 additions & 1 deletion postinstall/proxmox-cleanup.sh
Original file line number Diff line number Diff line change
Expand Up @@ -82,6 +82,7 @@ OLD_SYSCTL=(
)

FOUND=0
KEEP=0
ACTIONS=()

#---------------------------------------------------------------
Expand All @@ -107,6 +108,29 @@ has_readonly_keys() {
echo "$content" | grep -qE '^[[:space:]]*(kernel\.random\.entropy_avail|kernel\.random\.(boot_id|uuid)|fs\.dentry-state|fs\.file-nr)[[:space:]]*='
}

sysctl_keys() {
# Settable keys in sysctl.d content ($1), one per line, sorted.
# Commented lines are inert and must not count.
local content="$1"
echo "$content" \
| grep -oE '^[[:space:]]*[a-z][a-z0-9._-]*[[:space:]]*=' \
| tr -d ' =' \
| sort -u
}

orphaned_keys() {
# Keys set by the superseded file ($1) that the replacement ($2) does NOT
# set, one per line.
#
# Removing a file purely because a newer generation exists loses whatever
# the newer one never picked up. On a real host the superseded tweaks file
# carried five keys the replacement had no equivalent for -- dirty
# writeback intervals, keepalive probe tuning, an inotify limit -- and all
# five would have gone silently. A backup makes that recoverable, not safe.
local old_content="$1" new_content="$2"
comm -23 <(sysctl_keys "$old_content") <(sysctl_keys "$new_content")
}

network_tier_from_path() {
# 99-proxmox-network-10gbe.conf -> 10gbe
local path="$1" base
Expand Down Expand Up @@ -158,8 +182,28 @@ scan() {
note high "$f" \
"sets read-only kernel statistics -- errors on every boot"
else
# Only call it superseded if the replacement actually covers it.
local current_content orphans
current_content=$(cat /etc/sysctl.d/98-proxmox-optimize.conf 2>/dev/null || echo "")
orphans=$(orphaned_keys "$content" "$current_content")

if [ -n "$orphans" ]; then
KEEP=$((KEEP + 1))
# Counts as "something to report", or the no-findings fallback
# prints "none" directly underneath this entry.
found_sysctl=1
printf ' %b[KEEP]%b %s\n' "$CYAN" "$NC" "$f"
printf ' overrides 98-proxmox-optimize.conf, but sets %s key(s) it does not:\n' \
"$(echo "$orphans" | wc -l)"
while IFS= read -r orphan_key; do
printf ' %s\n' "$orphan_key"
done <<< "$orphans"
printf ' NOT removed -- fold these into 98-proxmox-optimize.conf first.\n'
continue
fi

note med "$f" \
"superseded by 98-proxmox-optimize.conf, which it currently overrides by sort order"
"superseded by 98-proxmox-optimize.conf, which covers every key it sets"
fi
found_sysctl=1
done
Expand Down Expand Up @@ -209,6 +253,9 @@ scan() {
else
echo -e "${YELLOW}${FOUND} superseded artefact(s) found.${NC}"
fi
if [ "$KEEP" -gt 0 ]; then
echo -e "${CYAN}${KEEP} file(s) kept: they still set keys nothing else does.${NC}"
fi
}

#---------------------------------------------------------------
Expand Down
125 changes: 106 additions & 19 deletions postinstall/proxmox-disk-errors.sh
Original file line number Diff line number Diff line change
Expand Up @@ -50,6 +50,13 @@
# completely unrelated, healthy pool lost their I/O. SMART reported PASSED
# throughout.
#
# Generalised from the hardening Derek wrote by hand during that incident.
# Two details are his and were reverted to after the generated versions
# proved worse: addressing drives by /dev/disk/by-id rather than sdX, and
# matching the udev rule on ID_MODEL rather than per-drive serial. Both
# matter for the same reason -- the protection has to survive a reboot or a
# disk swap without anyone remembering to re-run this.
#
# SAFETY -- READ THIS:
# SCT ERC is only correct BECAUSE there is redundancy. Telling a drive in a
# NON-redundant pool to give up early tells it to abandon data it might
Expand Down Expand Up @@ -179,6 +186,39 @@ base_device() {
return 0
}

stable_device_path() {
# A /dev/disk/by-id path for $1, or /dev/$1 if none exists.
#
# Reverted to Derek's original approach from the incident scripts, which
# addressed drives by /dev/disk/by-id. The generated version used bare sdX
# names and was worse: kernel names are assigned in discovery order and are
# NOT stable across reboots, so a boot-time unit that reasserts drive
# settings by kernel name can target a different disk than the one it was
# written for. On a host where some drives take the setting and others
# cannot, that is exactly how the wrong drive ends up unprotected.
#
# ata-/nvme- links carry model and serial and are preferred; wwn- links are
# stable too but opaque, so they are only a fallback.
local dev="$1" link base fallback=""

for link in /dev/disk/by-id/*; do
[ -e "$link" ] || continue
base=$(basename "$link")
case "$base" in *-part[0-9]*) continue ;; esac
[ "$(readlink -f "$link")" = "/dev/$dev" ] || continue
case "$base" in
wwn-*) [ -z "$fallback" ] && fallback="$link" ;;
*) echo "$link"; return 0 ;;
esac
done

if [ -n "$fallback" ]; then
echo "$fallback"
return 0
fi
echo "/dev/$dev"
}

pool_members() {
# Base device names backing pool $1, one per line, deduplicated.
local pool="$1" member dev
Expand Down Expand Up @@ -285,26 +325,48 @@ write_erc_service() {
return 0
fi

# Resolve to stable by-id paths at generation time. The helper must not
# depend on kernel names surviving a reboot -- see stable_device_path.
local dev paths=()
for dev in "${devices[@]}"; do
paths+=("$(stable_device_path "$dev")")
done

# SCT ERC is volatile: it is lost on a power cycle (though usually not on a
# warm reboot), so it must be reasserted at every boot rather than set once.
cat > "$ERC_HELPER" << EOF
{
cat << EOF
#!/bin/bash
# Reassert SCT ERC on redundant pool members.
# Installed by: proxmox-disk-errors.sh -- do not edit, changes are overwritten.
#
# SCT ERC does not persist across a power cycle. Without this, the setting
# silently reverts to the factory default (usually Disabled) and the drive goes
# back to retrying without bound.
#
# Drives are addressed by /dev/disk/by-id, not sdX: kernel names are assigned
# in discovery order and a drive that moves between boots would otherwise have
# the setting applied to whatever took its old name.

EOF
for dev in "${paths[@]}"; do
printf 'for_each_drive+=("%s")\n' "$dev"
done
cat << EOF

for dev in ${devices[*]}; do
[ -b "/dev/\$dev" ] || continue
smartctl -l scterc,${ERC_DECISECONDS},${ERC_DECISECONDS} "/dev/\$dev" >/dev/null 2>&1 \\
&& logger -t zfs-disk-erc "SCT ERC ${ERC_DECISECONDS}ds set on \$dev" \\
|| logger -t zfs-disk-erc "failed to set SCT ERC on \$dev"
for drive in "\${for_each_drive[@]}"; do
# A drive that has been pulled or replaced must not fail the unit.
[ -e "\$drive" ] || { logger -t zfs-disk-erc "absent, skipped: \$drive"; continue; }
if smartctl -l scterc,${ERC_DECISECONDS},${ERC_DECISECONDS} "\$drive" >/dev/null 2>&1; then
logger -t zfs-disk-erc "SCT ERC ${ERC_DECISECONDS}ds set on \$drive"
else
logger -t zfs-disk-erc "failed to set SCT ERC on \$drive"
fi
done

exit 0
EOF
} > "$ERC_HELPER"
chmod +x "$ERC_HELPER"

cat > "$ERC_SERVICE" << EOF
Expand Down Expand Up @@ -349,24 +411,49 @@ write_udev_rule() {
echo "# up on their behalf. The 30s default is far longer than any healthy SATA"
echo "# I/O; ${NO_SCT_TIMEOUT}s converts a stall into an error ZFS can actually repair from."
echo "#"
echo "# Matched on serial so the rule survives device renaming (sdc is not stable)."
echo "# Matched on MODEL, not serial -- reverted to Derek's original incident"
echo "# rule, which matched ENV{ID_MODEL} and worked better than the generated"
echo "# per-serial version that briefly replaced it."
echo "#"
echo "# Whether a drive supports SCT ERC is a property of the MODEL, so a"
echo "# replacement of the same model needs the same backstop -- and would not"
echo "# get it from a serial-specific rule until somebody remembered to re-run"
echo "# this script. Fitting a replacement disk is exactly the moment nobody is"
echo "# thinking about kernel timeouts."
echo "#"
echo "# DEVTYPE==\"disk\" restricts this to whole disks. A partition carries the"
echo "# same serial but has no device/timeout attribute of its own -- without the"
echo "# restriction udev retries the assignment against every partition and logs a"
echo "# failure for each."
echo "# same model but has no device/timeout attribute of its own -- without the"
echo "# restriction udev retries the assignment against every partition and logs"
echo "# a failure for each."
echo ""

# One rule per distinct model, rather than one per drive.
local models=() model seen
for dev in "${devices[@]}"; do
serial=$(udevadm info --query=property --name="/dev/$dev" 2>/dev/null | \
sed -n 's/^ID_SERIAL_SHORT=//p' | head -1)
if [ -n "$serial" ]; then
echo "ACTION==\"add|change\", SUBSYSTEM==\"block\", ENV{DEVTYPE}==\"disk\", ENV{ID_SERIAL_SHORT}==\"${serial}\", ATTR{device/timeout}=\"${NO_SCT_TIMEOUT}\""
else
# No stable serial exposed; fall back to the kernel name and say
# so, rather than silently writing a rule that matches nothing.
echo "# WARNING: no ID_SERIAL_SHORT for ${dev}, matching on kernel name (not stable across reboots)"
echo "ACTION==\"add|change\", SUBSYSTEM==\"block\", ENV{DEVTYPE}==\"disk\", KERNEL==\"${dev}\", ATTR{device/timeout}=\"${NO_SCT_TIMEOUT}\""
model=$(udevadm info --query=property --name="/dev/$dev" 2>/dev/null | \
sed -n 's/^ID_MODEL=//p' | head -1)
if [ -z "$model" ]; then
serial=$(udevadm info --query=property --name="/dev/$dev" 2>/dev/null | \
sed -n 's/^ID_SERIAL_SHORT=//p' | head -1)
if [ -n "$serial" ]; then
echo "# ${dev}: no ID_MODEL exposed, falling back to serial"
echo "ACTION==\"add|change\", SUBSYSTEM==\"block\", ENV{DEVTYPE}==\"disk\", ENV{ID_SERIAL_SHORT}==\"${serial}\", ATTR{device/timeout}=\"${NO_SCT_TIMEOUT}\""
else
echo "# WARNING: no ID_MODEL or ID_SERIAL_SHORT for ${dev}; kernel name is not stable across reboots"
echo "ACTION==\"add|change\", SUBSYSTEM==\"block\", ENV{DEVTYPE}==\"disk\", KERNEL==\"${dev}\", ATTR{device/timeout}=\"${NO_SCT_TIMEOUT}\""
fi
continue
fi

seen=0
for m in "${models[@]:-}"; do
[ "$m" = "$model" ] && { seen=1; break; }
done
[ "$seen" -eq 1 ] && continue
models+=("$model")

echo "# ${model} -- no SCT ERC support"
echo "ACTION==\"add|change\", SUBSYSTEM==\"block\", ENV{DEVTYPE}==\"disk\", ENV{ID_MODEL}==\"${model}\", ATTR{device/timeout}=\"${NO_SCT_TIMEOUT}\""
done
} > "$UDEV_RULE"

Expand Down
10 changes: 10 additions & 0 deletions postinstall/proxmox-optimize.sh
Original file line number Diff line number Diff line change
Expand Up @@ -219,11 +219,21 @@ net.core.netdev_max_backlog=8192
net.core.somaxconn=8192
net.ipv4.tcp_fin_timeout=30
net.ipv4.tcp_keepalive_time=300
net.ipv4.tcp_keepalive_probes=3
net.ipv4.tcp_keepalive_intvl=30
net.ipv4.tcp_tw_reuse=1

# File System
fs.file-max=2097152
fs.inotify.max_user_watches=524288
fs.inotify.max_user_instances=512

# Deliberately NOT set here: vm.dirty_expire_centisecs and
# vm.dirty_writeback_centisecs. Raising them keeps dirty pages in memory
# longer, which trades a measurable amount of unflushed data against a small
# throughput gain. That is a defensible choice on a host with a UPS and a
# reckless one without, so it is left to the operator rather than shipped as a
# default -- this file otherwise holds nothing that risks data on power loss.
EOF

# Bridge netfilter: NOT a Proxmox requirement, despite being widely repeated as
Expand Down
52 changes: 50 additions & 2 deletions postinstall/proxmox-power-management.sh
Original file line number Diff line number Diff line change
Expand Up @@ -330,7 +330,18 @@ for host in /sys/class/scsi_host/host*/; do
CURRENT=$(tr -d ' ' < "${host}link_power_management_policy" 2>/dev/null)

if [[ " $ZFS_HOSTS " == *" $HOSTNAME_ID "* ]]; then
echo " ${HOSTNAME_ID}: backs a ZFS pool, leaving at '$CURRENT'"
# Assert max_performance rather than merely skipping. Skipping
# prevents this script making things worse, but leaves a controller
# an EARLIER run already put into a power-saving state -- which is
# the situation on any host that ran a previous version. The disks
# holding the VMs are the last place to save a watt.
if [[ "$CURRENT" == "max_performance" ]] || [[ "$CURRENT" == "keep_firmware_settings" ]]; then
echo " ${HOSTNAME_ID}: backs a ZFS pool, already '$CURRENT'"
elif echo "max_performance" > "${host}link_power_management_policy" 2>/dev/null; then
echo " ${HOSTNAME_ID}: backs a ZFS pool, '$CURRENT' -> max_performance"
else
echo -e " ${HOSTNAME_ID}: ${YELLOW}backs a ZFS pool but could not clear '$CURRENT'${NC}"
fi
SATA_SKIPPED=$((SATA_SKIPPED + 1))
continue
fi
Expand Down Expand Up @@ -360,7 +371,7 @@ done
set -e

[ $SATA_COUNT -gt 0 ] && echo "Configured $SATA_COUNT SATA controllers" || echo "No SATA controllers needed changes"
[ $SATA_SKIPPED -gt 0 ] && echo "Skipped $SATA_SKIPPED controller(s) backing ZFS pools"
[ "$SATA_SKIPPED" -gt 0 ] && echo "$SATA_SKIPPED controller(s) backing ZFS pools held at max_performance"

#############################################
# Network Power Management
Expand Down Expand Up @@ -581,6 +592,43 @@ for usb in /sys/bus/usb/devices/*/power/control; do
fi
fi
done

# Hold SATA controllers that back a ZFS pool at max_performance.
#
# The sysfs link power policy does not persist across a reboot, so setting it
# once at install time is not enough -- it reverts to whatever the kernel
# defaults to for that controller. Reasserting it here is what makes it stick.
#
# The disks holding the VMs are the last place to save a watt: link power
# management parks the SATA link between commands and adds wake latency to
# every I/O, which works directly against the bounded retry times configured by
# proxmox-disk-errors.sh.
ZFS_HOSTS=""
if command -v zpool >/dev/null 2>&1; then
for pool in $(zpool list -H -o name 2>/dev/null); do
while read -r member; do
[ -z "$member" ] && continue
memberdev=$(readlink -f "$member" 2>/dev/null)
memberdev=${memberdev#/dev/}
memberdev=$(echo "$memberdev" | sed -E 's/(nvme[0-9]+n[0-9]+)p[0-9]+$/\1/; s/^([a-z]+)[0-9]+$/\1/')
hostpath=$(readlink -f "/sys/block/${memberdev}/device" 2>/dev/null) || continue
hostid=$(echo "$hostpath" | grep -oE 'host[0-9]+' | head -1)
[ -n "$hostid" ] && ZFS_HOSTS="$ZFS_HOSTS $hostid"
done < <(zpool list -vHP "$pool" 2>/dev/null | awk '$1 ~ /^\/dev\// {print $1}')
done
fi

for host in /sys/class/scsi_host/host*/; do
[ -f "${host}link_power_management_policy" ] || continue
hostid=$(basename "$host")
case " $ZFS_HOSTS " in
*" $hostid "*)
CURRENT=$(tr -d ' ' < "${host}link_power_management_policy" 2>/dev/null)
[ "$CURRENT" != "max_performance" ] && \
echo "max_performance" > "${host}link_power_management_policy" 2>/dev/null || true
;;
esac
done
EOF

chmod +x /usr/local/bin/proxmox-power-apply.sh
Expand Down
Loading