Skip to content

Support for function 5 and 6. #33

Description

@GoogleCodeExporter
What steps will reproduce the problem?
1. The modbus slave I have does not support function 16 for setting register, 
only function 6.
2. Same goes for function 15, not supported, only function 5.

This is a thermostat from Delta automation.
Reading registers and coils works perfectly.
But for full functionality I need to be able to set the new target temperature, 
this is done with function 6 to address 0x1001. And I need to switch the 
thermostat between run/stop mode, a single coil at address 0x0814.

Any possibility this could make it in to the library?

Original issue reported on code.google.com by johan.wi...@gmail.com on 17 Jul 2014 at 1:59

Activity

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment