Skip to content

Repository files navigation

HA Smart Dehumidifier

🇺🇦 Українською

A Home Assistant integration that turns a plain smart switch into a full "smart dehumidifier" device, plus a matching Lovelace card.

All the logic — turning the fan on/off, auto mode, manual mode, timers — runs inside the integration itself. You don't need to create any input_boolean, input_number, timer helpers or automations; everything below is provided out of the box.

Card — auto mode active

Features

  • Wraps any switch entity (a smart plug, a relay, anything) as a humidifier device with target-humidity control.
  • Auto mode: calculates a recommended target humidity from an adjacent ("reference") room's humidity (optionally correcting for the temperature difference between the two rooms), then drives the fan with hysteresis so it doesn't chatter.
  • Manual mode: a one-tap override that runs the fan for a configurable duration, then pauses auto mode for a while so it doesn't immediately override your manual action.
  • Works with zero optional sensors too — see Using it without auto-humidity sensors below.
  • A custom Lovelace card with a circular slider, live status, and an extensive visual editor (layout, colors, fonts, animations) — no YAML required.

Installation via HACS

  1. HACS → Custom repositories → add this repository (category: Integration).
  2. Install "HA Smart Dehumidifier", then restart Home Assistant (a reload is not enough after the first install).
  3. Settings → Devices & services → Add integration → HA Smart Dehumidifier.

Setting up a device

When you add the integration you'll be asked for:

Field Required? What it's for
Fan switch Yes The real switch entity that physically turns the fan on/off. Without it the device can't control anything.
Humidity sensor (dehumidifier room) No Current humidity in the room the dehumidifier is in. Needed for auto mode and for the "current humidity" readout.
Temperature sensor (dehumidifier room) No Used together with the two fields below for temperature-corrected calculations.
Humidity sensor (adjacent room), % No Humidity of a reference/adjacent room, used to calculate a recommended target.
Temperature sensor (adjacent room) No See Why two temperature sensors below.

Only the fan switch is required. Leave any sensor field empty if you don't have it — the device still works; it just falls back to simpler behavior (see the two usage modes below). You can add or change any of these later without recreating the device: Settings → Devices & services → HA Smart Dehumidifier → ⋯ → Reconfigure.

Once the device is created, the integration adds these entities:

Entity Type Purpose
humidifier.<name> humidifier The main entity — on/off, target humidity, current humidity. This is what you point the card at.
sensor.<name>_status sensor Current status: off / connecting / auto / idle / manual / manual_auto / pause — see the table below.
sensor.<name>_recommended_humidity sensor The auto-calculated recommended target (only meaningful with the humidity sensors configured).
sensor.<name>_absolute_humidity_room sensor Absolute humidity (g/m³) of the dehumidifier's room.
sensor.<name>_absolute_humidity_neighbor sensor Absolute humidity (g/m³) of the adjacent room.
switch.<name>_auto_mode switch Toggles auto mode on/off.
button.<name>_manual_toggle button Same action as the card's "MANUAL" button.
number.<name>_delta number See Configuration reference.
number.<name>_min_humidity number
number.<name>_max_humidity number
number.<name>_manual_runtime number
number.<name>_manual_pause number

Why two temperature sensors

The same relative humidity at a different temperature holds a different amount of water in the air, so comparing raw percentages between two rooms isn't accurate. If both temperature sensors are set, the integration:

  1. converts the adjacent room's humidity to absolute humidity (g/m³) using its own temperature (Magnus-Tetens formula);
  2. adds the configured delta — also in g/m³ in this mode — to that value;
  3. converts the result back to a relative humidity percentage using the dehumidifier room's own temperature — that's the recommended / target humidity you see on the card.

If either temperature sensor is missing, the integration automatically falls back to a direct percentage comparison instead: delta is then in percentage points, added straight to the adjacent room's humidity reading. This switch is fully automatic — it also changes the unit of the delta number entity (% or g/m³) — you never need to flip anything by hand, adding or removing a temperature sensor is enough.

Adding the card

Create the device first (see above), then add the card — without a device the card has nothing to show.

The card registers itself automatically; you don't need to add a Lovelace resource by hand (see If the card doesn't show up if it doesn't). In YAML mode this is all you need:

type: custom:ha-smart-dehumidifier

Then open the card's visual editor and, on the "Entities" tab 🔗, pick the Device (HA Smart Dehumidifier) you created — its main humidifier entity. Everything else (the fan switch, sensors, status, auto-mode switch, the number entities) is discovered by the card automatically; you never assign them by hand.

Or, in YAML, the same thing in one step:

type: custom:ha-smart-dehumidifier
entity: humidifier.smart_xxx

All visual settings (layout, the arc, colors, animations, the 7-segment font, bottom buttons, badge, and so on) are configured in the same visual editor — see The visual editor below for a map of every tab.

How to use it

Using it with auto-humidity sensors

This is the mode you get once at least the current-humidity sensor (and ideally the adjacent-room sensor and both temperature sensors) are configured:

  1. Turn the device ON (bottom-left button).
  2. Leave auto mode on (it's on by default — the badge at the top of the card shows "AUTO xx%"). The integration keeps recalculating a recommended target humidity from your sensors and keeps the fan in sync with it automatically.
  3. Tune the calculation to your room once, if needed, via number.<name>_delta / _min_humidity / _max_humidity (or the gear icon on the card) — see Configuration reference.
  4. That's it — day to day, you shouldn't need to touch anything.

If you drag the arc, tap +/-, or tap the target-humidity panel, that becomes a one-off manual override of the target value and switches auto mode off immediately (so the next sensor update doesn't overwrite your choice) — toggle switch.<name>_auto_mode back on whenever you want the automatic calculation back.

Using it without auto-humidity sensors

If you only set the fan switch (or don't have the adjacent-room sensor), the device is still fully usable — it simply has nothing to calculate a target from, so you drive it manually:

  1. Turn the device ON.
  2. Set a target humidity yourself with the arc / +/- buttons / target panel. Manual target changes always turn auto mode off, so this is the normal way to operate here — there's nothing to switch off first.
  3. If you also have just a current-humidity sensor for the room (without the adjacent-room one), the fan will still turn on/off around whatever target you set, using the same hysteresis logic as auto mode — you're simply supplying the target by hand instead of letting the integration calculate it.
  4. With no humidity sensor at all, use the MANUAL button (bottom-right) instead: it runs the fan for a fixed duration (number.<name>_manual_runtime, 20 minutes by default), then pauses for a while (number.<name>_manual_pause) before it would consider auto behavior again — press it again any time to start another run, or press it while running to stop early.

How auto mode works

The fan turns on and off using an asymmetric hysteresis around the target humidity (which auto mode calculates for you — see Why two temperature sensors — or which you set by hand in manual use):

  • Turns ON as soon as the current humidity reaches or exceeds the target (current >= target) — no delay, it reacts immediately.
  • Turns OFF only once the current humidity drops below the target by the configured hysteresis (current <= target − hysteresis, 5% by default).

This works the same regardless of why the "current − target" gap changed — whether the humidity itself dropped, or you simply raised the target. For example, with a 5% hysteresis and a 65% target: the fan turns on as soon as humidity reaches 65%, and turns off once it drops to 60% — or immediately, if you raise the target to 65%+ while humidity is already at 60% or below. The margin only applies to turning off, so the relay doesn't chatter every time humidity briefly touches the target.

A few more behavior notes:

  • Manually changing the target (the slider, +/- buttons, or tapping the target panel) turns auto mode off immediately, so the very next sensor update doesn't overwrite your choice.
  • The MANUAL button always inverts the fan's actual state: if it's currently running, it pauses it; if it's off, it starts a manual timer run (duration is configurable, 20 min by default).
  • After a manual run ends (timer elapsed or turned off by hand), a pause period starts (20 min by default) during which auto mode won't touch the fan — this is intentional, so your manual intervention isn't immediately overridden by automation.
  • The physical switch is also taken into account: turning it on "by hand" (not through auto mode) starts a manual run; turning it off during a manual run starts the pause.

The device's status sensor (sensor.<name>_status) reflects which of these is currently driving the fan:

Status Meaning
off Device is off.
connecting Device is on, but the current-humidity sensor isn't available yet (typically the first few seconds after HA restarts).
auto The fan is actually running because humidity triggered it.
idle Device is on, fan is idle — humidity hasn't reached the target yet.
manual Manual mode is running, humidity hasn't triggered yet.
manual_auto Manual mode is running and humidity has triggered at the same time.
pause Manual mode just ended — short pause before automatic detection resumes.

The visual editor

Open the card's settings (gear icon) to get a tabbed visual editor — no YAML editing needed for any of this:

Tab Covers
🔗 Entities The device (humidifier) the card points at.
📐 Layout Card padding, corner radius, alignment, and the "glass" width/height proportions for desktop/wide screens.
🔵 Arc & handle The circular slider — track/handle colors, thickness, drag handle style.
🪄 Auto humidity The "AUTO xx%" badge shown at the top when auto mode is on.
💧 Current humidity The big 7-segment readout — sizes, weight, spacing for the whole-number, decimal, and % parts.
🎯 Target humidity panel The number/±-buttons panel under the readout.
🔘 Bottom buttons OFF / fan-status / MANUAL buttons, their labels and icons, and the status badge.
Visual effects The background fan animation, the orbiting "comet", and particle effects.

Configuration reference

These can be changed two ways: live, via the gear icon on the card (saved permanently, survives restarts); or once, as the starting values, via Settings → Devices & services → HA Smart Dehumidifier → Configure.

Setting Default Range
Humidity delta vs. adjacent room 3.75 (% or g/m³, automatic) 0–10
Minimum recommended humidity 65% 0–100
Maximum recommended humidity 85% 0–100
Hysteresis tolerance (Configure only) 5%
Manual mode duration 20 min 1–180
Pause after manual mode 20 min 1–180

Min/max recommended humidity only clamp the auto-calculated target. Setting the target by hand (arc, +/- buttons, target panel) always accepts the full 0–100% range regardless of these limits.

If the card doesn't show up ("Custom element doesn't exist")

  1. Confirm the integration actually loaded: Settings → System → Logs → search for ha_smart_dehumidifier. A resource registration error will tell you what to fix.
  2. Open the dashboard in a browser, F12 → Network, reload, and check the request for /ha_smart_dehumidifier_files/index.js — it should be 200, not 404. A 404 means the integration didn't load (check the logs) or Home Assistant needs a full restart (not a reload) after installing via HACS.
  3. Hard-refresh the browser cache (Ctrl+Shift+R / Cmd+Shift+R).
  4. If none of that helps, add the resource by hand: Settings → Dashboards → ⋮ → Resources → Add resource → URL /ha_smart_dehumidifier_files/index.js, type JavaScript Module.

Screenshots

Auto mode Off Visual editor
Auto mode Off state Visual editor

Development / contributing

  • custom_components/ha_smart_dehumidifier/ — the integration (Python).
  • custom_components/ha_smart_dehumidifier/www/ — the card (JS/Lit), auto-served by the integration.
  • CI: hassfest and HACS validation (.github/workflows/).

Issues and pull requests are welcome.

License