Docs only, for the merged #53 and #52.

  • docs/parity.md: the sigma on wt% and at% row says quantifyWithSigma takes thicknessSigmaNm: (Cliff-Lorimer) and doseRelativeSigma: (zeta, cross section), names the four new sigma fields, and gives the coverage the planted-case tests hold (0.63 to 0.71 within 1 sigma, 0.93 to 0.97 within 2 sigma). The open-areas list said Si 8.7 % low; since the absorption-truth test counts the Si internal-fluorescence peak it reads 20 % low against the whole planted peak, as the EDS note already says.
  • docs/open-items.md: item 9 keeps only the detector term and the per-pixel sigma map.

Already current on main: the Si internal-fluorescence note and open-items item 3 (#52).

Remains: the take-off angle and map sigma (#55), the dead-layer row (#50) and the item 8 pile-up sentence (#56), once those merge.

Test evidence: docs only; the CI gate staying green is the test.

🤖 Generated with Claude Code

…n the parity list

parity.md: the sigma on wt% and at% row says the per-spectrum quantifyWithSigma takes thicknessSigmaNm (Cliff-Lorimer) and
doseRelativeSigma (zeta, cross section), names the four new sigma fields, and gives the coverage the planted-case tests hold
(0.63 to 0.71 within 1 sigma, 0.93 to 0.97 within 2 sigma). The open-areas list said Si 8.7 % low; since the absorption-truth
test counts the Si internal-fluorescence peak it is 20 % low against the whole planted peak, as the EDS note and open-items
already say.

open-items.md: item 9 keeps only the detector term and the per-pixel sigma map.

The Si internal-fluorescence note and open-items item 3 were already updated by the PR that pinned the bias. The dead-layer
row, the take-off-angle and map sigma, and the pile-up sentence of item 8 wait for their PRs to merge.

Done: rows for the thickness and dose sigma. Next: the detector and map sigma rows and the dead-layer row when they merge.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@Paullo9 Paullo9 self-assigned this Oct 31, 2026
@Paullo9
Paullo9 merged commit 231ea5b into main Oct 31, 2026
7 checks passed
@Paullo9
Paullo9 deleted the issue-15-docs-catchup branch October 31, 2026 19:45
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant