@DenBir

The Power Brain Wallbox Solar use as default 3-phase charging and with a switch in the UI you can set to 1-phase charging.
It would be great if you add this switch in your HA Power Brain integration.

Thanks,
Dennis

Activity

  1. dylan09 commented on Nov 15, 2023

    @dylan09

    1+

  2. mb-software commented on Nov 26, 2023

    @mb-software
    Owner

    Hi,
    unfortunately I do not own a powerbrain wallbox with the phase switching feature and have no possibility to develop and test it.
    If anyone wants to contribute, please feel free.

  3. DenBir commented on Nov 26, 2023

    @DenBir
    Author

    Hi @mb-software ,

    I have a WB with phase switching (with the provided upgrade kit) but no knowlegde for Python.

    Of course, I can provide you with the necessary information and then be happy to test it.

    POST /cnf?cmd=set_device HTTP/1.1
    Property: allow_ph_sw
    Value: true / false
    Property path: devices[0].allow_ph_sw
    2023-11-26 16_48_18-cFos Power Brain - Overview und 3 weitere Seiten - Persönlich – Microsoft​ Edge

    I found on the homepage the following guide https://www.cfos-emobility.de/en/cfos-charging-manager/documentation/automatic-phase-switching.htm

    Set up an RFID for 3-phase charging in the user settings and set "Method" as the Charging Manager Output: GET and "URL" for this card:
    http://localhost/cnf?cmd=modbus&device=evse&write=8087&value=0
    For single-phase charging, you can set up an RFID card with Charging Manager Output "Method": GET and as "URL":
    http://localhost/cnf?cmd=modbus&device=evse&write=8087&value=1
    The prerequisite is that the wallbox runs as a master with activated load management.

    and here the the necessary register 8087 https://www.cfos-emobility.de/en/cfos-power-brain/modbus-registers.htm

    hth

  4. Frenchrapper commented on Nov 7, 2024

    @Frenchrapper

    For a phase switch you can add the following code to your configuration.yaml:

    command_line:
      - switch:
          name: cfos_phase_switch
          command_on: "curl -s 'http://user:password@192.168.0.0/cnf?cmd=modbus&device=evse&write=8087&value=1'"
          command_off: "curl -s 'http://user_:password@192.168.0.0/cnf?cmd=modbus&device=evse&write=8087&value=0'"
    

    You have to replace user (often admin), password and the IP adress.
    After restart you will find a integration called "Command line" and there the entity "cfos_phase_switch".
    On (=1) is 1-phase and off (=0) is 3-phase.
    Yo can ckeck the state using the following URL: http://192.168.0.0/cnf?cmd=modbus&device=evse&read=8087

  5. bufu2012 commented on Mar 6, 2025

    @bufu2012

    +1

  6. guibrazlima commented on Mar 14, 2026

    @guibrazlima

    This has been implemented in PR #92.

    A new select entity Phase Mode is added for each EVSE with options 1 phase and 3 phases. It uses Modbus register 8044 (used_phases bitfield: 1=L1 only, 7=L1+L2+L3).

    There is also a new service powerbrain.set_phase_mode for use in automations:

    service: powerbrain.set_phase_mode
    data:
      dev_id: E1
      phases: 1
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions