You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Rushton turbine stirred-tank CFD in STAR-CCM+: steady MRF and transient sliding mesh validated against the published Power Number (Po 4.85 / 4.89 vs 5.0), after a dimensional audit traced a 2.1× discrepancy to a blade placement defect.