Repository navigation
Conversation
This was referenced Oct 7, 2026
This branch has not been deployed
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Stacked performance slice for #144. Base is
fix/144-smart-interop-p0(PR #145) so this work stays isolated from the active semantic/export and ARSAS packaging lanes.Goal
Make runtime acquisition proportional to the selected signals/RCBs, not to the size of the IED.
Smart means less network work with stronger context, not more probing.
Changes
TargetReportControlReferencesto availability options;Anti-naive boundaries
Regression
Pure selector tests prove:
Consumer plan
ARSAS #446 should eventually pass only concrete live RCB references produced by canonical static coverage + RCB family resolution. The ARSAS engine lock is intentionally untouched here because active PR #425 currently owns that integration surface.
Canonical-to-live target resolution
This slice now also keeps target selection inside ARIEC61850 rather than forcing ARSAS to reproduce IEC 61850 semantics:
CanonicalLiveModelAdapter.FromSclWorkspace(...)gives Open-SCL a source-correct canonical ingress instead of relabeling the SCL design model as live discovery;MmsCanonicalStaticRcbTargetResolverresolves canonical covered DataSets to concrete live RCB references using only exact configured-reference identity or exact live DatSet binding + BRCB/URCB family;