Log the readings a warm-up step used and why the warm-up ended - #1104
Merged
Merged
Conversation
The progress line on close showed sensor and power read again after the step, which could differ from the reading the step was planned with. It now shows the reading the step used. The done line says whether the setpoint reached the off temperature or the cooler was idle, with the readings. RampStep gains an idle field. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
On iag50cam the progress line showed 5 % power at 14:52 while the step had read 0 %, because the log read the hardware again after the step.
cooler idle at setpoint 5.7 °C, sensor 0.2 °C, power 0 %orsetpoint at 20.0 °C.RampStephas a new fieldidle(default False, so existing callers in pyobs-asi/pyobs-qhyccd are unaffected).Tests: cooling tests pass, full suite without integration/xmpp 2782 passed. ruff, black, pyrefly clean.