6 changes: 6 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -9,6 +9,12 @@ Entries for 2.6.0 to 2.14.0 were generated from commit subjects. Older entries w

## [Unreleased]

### Changed

- The warm-up progress line on close shows the sensor temperature and power the last step was planned with,
instead of reading them again after the step. The done line says why the warm-up ended (setpoint reached, or
cooler idle, with the readings). `RampStep` has a new field `idle`.

## [2.29.1] - 2026-11-25

### Changed
Expand Down
37 changes: 24 additions & 13 deletions pyobs/mixins/coolingramp.py
Original file line number Diff line number Diff line change
Expand Up @@ -86,6 +86,9 @@ def __init__(
self._cooling_commanded: float | None = None
self._cooling_event = asyncio.Event()
self._cooling_failures = 0
# sensor temperature and power the last warm-up step was planned with, and how the last ramp ended
self._cooling_reading: tuple[float | None, int | None] = (None, None)
self._cooling_end: str | None = None

self._cooling_task = self.add_background_task(self._cooling_ramp_loop, True) # type: ignore[attr-defined]

Expand Down Expand Up @@ -197,6 +200,7 @@ async def _cooling_warm_up(self, timeout: float) -> None:
"""Runs the warm-up ramp to its end. Logs when it starts, about every _WARMUP_LOG_INTERVAL seconds while it
runs, and when it is done, so the log shows why the module takes long to stop."""
start = time.monotonic()
self._cooling_reading, self._cooling_end = (None, None), None
delay = await self._cooling_tick()
if self._cooling_target is None:
return # cooler was off already, or switched off in the first step
Expand All @@ -213,25 +217,19 @@ async def _cooling_warm_up(self, timeout: float) -> None:
delay = await self._cooling_tick()
now = time.monotonic()
if self._cooling_target is not None and now >= next_log:
await self._cooling_log_warm_up(start + timeout - now)
self._cooling_log_warm_up(start + timeout - now)
next_log = now + _WARMUP_LOG_INTERVAL
log.info("Warm-up done after %s, cooling is off.", _duration(time.monotonic() - start))
end = f", {self._cooling_end}" if self._cooling_end else ""
log.info("Warm-up done after %s%s, cooling is off.", _duration(time.monotonic() - start), end)

async def _cooling_log_warm_up(self, left: float) -> None:
# only for the log, the next tick reports a real problem
try:
sensor = await self._get_sensor_temperature()
except Exception:
sensor = None
try:
_, _, power = await self._get_cooling_hardware()
except Exception:
power = None
def _cooling_log_warm_up(self, left: float) -> None:
"""Logs the progress, with the readings the last step was planned with."""
sensor, power = self._cooling_reading
log.info(
"Warming up: setpoint %s, sensor %s, power %s, up to %s left.",
_temperature(self._cooling_commanded),
_temperature(sensor),
"unknown" if power is None else f"{power} %",
_power(power),
_duration(max(0.0, left)),
)

Expand Down Expand Up @@ -303,6 +301,15 @@ async def _cooling_tick(self) -> float | None:
sensor = await self._get_sensor_temperature()
_, _, power = await self._get_cooling_hardware()
step = self._cooling_ramp.next_step(commanded, enabled, setpoint, sensor, power)
if not enabled:
self._cooling_reading = (sensor, power)
if step.done:
self._cooling_end = (
f"cooler idle at setpoint {_temperature(commanded)}, sensor {_temperature(sensor)}, "
f"power {_power(power)}"
if step.idle
else f"setpoint at {_temperature(commanded)}"
)
if step.write:
await self._set_cooling_hardware(step.enabled, step.setpoint)
self._cooling_commanded = step.setpoint
Expand All @@ -321,6 +328,10 @@ def _temperature(value: float | None) -> str:
return "unknown" if value is None else f"{value:.1f} °C"


def _power(value: int | None) -> str:
return "unknown" if value is None else f"{value} %"


def _duration(seconds: float) -> str:
return f"{seconds:.0f} s" if seconds < 90 else f"{seconds / 60:.0f} min"

Expand Down
7 changes: 5 additions & 2 deletions pyobs/utils/coolingramp.py
Original file line number Diff line number Diff line change
Expand Up @@ -29,13 +29,15 @@ class RampStep:
setpoint: Setpoint to write, None if the cooler is to be switched off.
done: Whether the ramp has reached its target after this step.
delay: Seconds to wait before asking for the next step (0 if done).
idle: Whether a warm-up stopped early because the cooler was idle.
"""

write: bool
enabled: bool
setpoint: float | None
done: bool
delay: float
idle: bool = False


class CoolingRamp:
Expand Down Expand Up @@ -148,9 +150,10 @@ def next_step(
if not enabled:
idle = sensor is not None and commanded >= sensor + IDLE_MARGIN and (power is None or power == 0)
self._idle_count = self._idle_count + 1 if idle else 0
if self._idle_count >= self.idle_steps or commanded >= goal or self.rate_warm is None:
stop_idle = self._idle_count >= self.idle_steps and commanded < goal
if stop_idle or commanded >= goal or self.rate_warm is None:
self._idle_count = 0
return RampStep(write=True, enabled=False, setpoint=None, done=True, delay=0.0)
return RampStep(write=True, enabled=False, setpoint=None, done=True, delay=0.0, idle=stop_idle)
else:
self._idle_count = 0
if commanded == goal:
Expand Down
24 changes: 18 additions & 6 deletions tests/mixins/test_coolingramp.py
Original file line number Diff line number Diff line change
Expand Up @@ -313,8 +313,10 @@ async def test_close_with_warmup_logs_start_progress_and_end(
await camera.close()
lines = [r.getMessage() for r in caplog.records if r.name == "pyobs.mixins.coolingramp"]
assert lines[0] == "Warming up from -9.0 °C towards -8.0 °C before closing, may take up to 30 s."
assert lines[1] == "Warming up: setpoint -8.0 °C, sensor -8.5 °C, power 80 %, up to 30 s left."
assert lines[-1].startswith("Warm-up done after ") and lines[-1].endswith("cooling is off.")
# sensor and power are the ones the step was planned with, read before the setpoint went to -8
assert lines[1] == "Warming up: setpoint -8.0 °C, sensor -9.5 °C, power 80 %, up to 30 s left."
assert lines[-1].startswith("Warm-up done after ")
assert lines[-1].endswith(", setpoint at -8.0 °C, cooling is off.")
assert len(lines) == 3


Expand All @@ -328,13 +330,23 @@ async def test_close_with_cooler_already_off_logs_no_warmup(caplog: pytest.LogCa


@pytest.mark.asyncio
async def test_warmup_progress_survives_failing_reads(caplog: pytest.LogCaptureFixture) -> None:
async def test_close_with_idle_cooler_logs_why_it_stopped_early(caplog: pytest.LogCaptureFixture) -> None:
camera = make_camera(cooling_rate_warm=600.0, cooling_close_timeout=30.0)
camera._cooling = camera._cooling._replace(temperatures={"CCD": -8.0, "Back": 3.0}, power=0) # setpoint -10
with caplog.at_level("INFO", logger="pyobs.mixins.coolingramp"):
await camera.close()
lines = [r.getMessage() for r in caplog.records if r.name == "pyobs.mixins.coolingramp"]
# idle from -7 (sensor + 1) on, off after the third idle reading at -5
assert lines[-1].endswith(", cooler idle at setpoint -5.0 °C, sensor -8.0 °C, power 0 %, cooling is off."), lines[
-1
]


def test_warmup_progress_without_readings_says_unknown(caplog: pytest.LogCaptureFixture) -> None:
camera = make_camera()
camera._cooling_commanded = -12.0
camera._get_sensor_temperature = AsyncMock(side_effect=RuntimeError("SDK error")) # type: ignore[method-assign]
camera._get_cooling_hardware = AsyncMock(side_effect=RuntimeError("SDK error")) # type: ignore[method-assign]
with caplog.at_level("INFO", logger="pyobs.mixins.coolingramp"):
await camera._cooling_log_warm_up(840.0)
camera._cooling_log_warm_up(840.0)
msg = "Warming up: setpoint -12.0 °C, sensor unknown, power unknown, up to 14 min left."
assert caplog.records[-1].getMessage() == msg

Expand Down
8 changes: 7 additions & 1 deletion tests/utils/test_coolingramp.py
Original file line number Diff line number Diff line change
Expand Up @@ -71,7 +71,13 @@ def test_disable_stops_early_when_sensor_stops_following() -> None:
assert ramp.next_step(6.0, False, None, sensor=5.0, power=0).setpoint == 7.0
assert ramp.next_step(7.0, False, None, sensor=5.0, power=0).setpoint == 8.0
step = ramp.next_step(8.0, False, None, sensor=5.0, power=0)
assert step.done and step.enabled is False and step.setpoint is None
assert step.done and step.enabled is False and step.setpoint is None and step.idle


def test_disable_at_the_end_point_is_not_an_idle_stop() -> None:
ramp = CoolingRamp(rate_warm=1.0, off_temperature=20.0, idle_steps=1)
step = ramp.next_step(20.0, False, None, sensor=5.0, power=0)
assert step.done and step.enabled is False and not step.idle


def test_disable_needs_idle_readings_in_a_row() -> None:
Expand Down
Loading